CS-PC30JKF-5
CS-PC36JKF-5
WARNING
PRECAUTION OF LOW TEMPERATURE
Indoor Unit
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2011.
Unauthorized copying and distribution is a violation of law.
Order No: PHAAM1111112A3
Outdoor Unit
CU-PC30JKF-5
CU-PC36JKF-5

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic CS-PC30JKF-5

  • Page 1 PRECAUTION OF LOW TEMPERATURE In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit. © Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2011. Unauthorized copying and distribution is a violation of law.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PAGE PAGE 1. Safety Precautions ..........3 2. Specification ............5 3. Refrigeration Cycle Diagram ......7 CS-PC30JKF-5 CU-PC30JKF-5....7 CS-PC36JKF-5 CU-PC36JKF-5....8 4. Technical Data ............9 Thermostat Characteristics ......9 Operation Characteristics......10 Discharge and Suction Pressure....14 5. Exploded View and Replacement Parts List ..............15...
  • Page 3: Safety Precautions

    1. Safety Precautions  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. ...
  • Page 4 21. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant contacts with fire. 22. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire. 23.
  • Page 5: Specification

    2. Specification Indoor CS-PC30JKF-5 CS-PC36JKF-5 Model Outdoor CU-PC30JKF-5 CU-PC36JKF-5 Performance Test Condition ISO 5151 (T3) ISO 5151 (T3) Phase, Hz Single, 50 Single, 50 Power Supply 6.92 8.84 Capacity BTU/h 23600 30200 kJ/h 24910 31820 Running Current 15.5 18.5 Input Power...
  • Page 6 Indoor CS-PC30JKF-5 CS-PC36JKF-5 Model Outdoor CU-PC30JKF-5 CU-PC36JKF-5 Height(I/D / O/D) mm (inch) 340 (13-13/32) / 795 (31-5/16) 340 (13-13/32) / 1170 (46-3/32) Dimension Width (I/D / O/D) mm (inch) 1150 (45-9/32) / 900 (35-7/16) 1150 (44-9/32) / 900 (35-7/16) Depth (I/D / O/D)
  • Page 7: Refrigeration Cycle Diagram

    3. Refrigeration Cycle Diagram CS-PC30JKF-5 CU-PC30JKF-5...
  • Page 8: Cs-Pc36Jkf-5 Cu-Pc36Jkf-5

    CS-PC36JKF-5 CU-PC36JKF-5...
  • Page 9: Technical Data

    4. Technical Data Thermostat Characteristics Cooling Soft Dry...
  • Page 10: Operation Characteristics

    Operation Characteristics 4.2.1 CS-PC30JKF-5 CU-PC30JKF-5  Cooling Characteristics [Condition] Room temperature: 27/19°C Operation condition: High fan speed Piping length: 5 m...
  • Page 11  Piping Length Characteristics [Condition] Room temperature: 27/19°C Operation condition: High fan speed Outdoor temperature: 35°C...
  • Page 12 4.2.2 CS-PC36JKF-5 CU-PC36JKF-5  Cooling Characteristics [Condition] Room temperature: 27/19°C Operation condition: High fan speed Piping length: 25 m...
  • Page 13  Piping Length Characteristics [Condition] Room temperature: 27/19°C Operation condition: High fan speed Outdoor temperature: 35°C...
  • Page 14: Discharge And Suction Pressure

    Discharge and Suction Pressure 4.3.1 CS-PC30JKF-5 CU-PC30JKF-5 Power source : 230V, 50Hz, 1 phase OUTDOOR AMBIENT TEMPERATURE 10°C 20°C 30°C 40°C 50°C 55°C ID WB °C Pdis Tsdis Pdis Tsdis Pdis Tsdis Pdis Tsdis Pdis Tsdis Pdis Tsdis °C °C °C...
  • Page 15: Exploded View And Replacement Parts List

    5. Exploded View and Replacement Parts List Indoor Unit Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
  • Page 16 REF NO. PART NAME & DESCRIPTION QTY. CS-PC30JKF-5 CS-PC36JKF-5 REMARK CHASSY COMPLETE CWD50C1477 ← FAN MOTOR DC 60W 3PH ARW42A8P60AC ← CROSS FLOW FAN COMPLETE CWH02C1044 ← SCREW - CROSS FLOW FAN CWH551146 ← BEARING ASS’Y CWH64C1005 ← EVAPORATOR COMPLETE...
  • Page 17: Outdoor Unit

    Outdoor Unit 5.2.1 CU-PC30JKF-5...
  • Page 18 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
  • Page 19 REF. NO. DESCRIPTION & NAME QTY. CU-PC30JKF-5 REMARK BASE PAN ASS’Y CWD52K1102 COMPRESSOR 2JD514D5AA03 ANTI-VIBRATION BUSHING CWH50055 NUT FOR COMP. MOUNT. CWH561049 GASKET FOR TERMINAL COVER CWB811017 CONDENSER COMPLETE CWB32C1778 OIL SEPARATER CWB161011 EXPANSION VALVE CWB051018J TUBE ASS'Y.(CAP TUBE) CWT024153 3-WAYS VALVE(GAS) CWB011429 STRAINER...
  • Page 20 5.2.2 CU-PC36JKF-5...
  • Page 22 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
  • Page 23 REF. NO. DESCRIPTION & NAME QTY. CU-PC36JKF-5 REMARK BASE PAN ASS’Y CWD52K1157 COMPRESSOR ZR47K3PFJ512 ANTI-VIBRATION BUSHING CWH501020 GASKET FOR TERMINAL COVER CWB811017 NUT FOR COMP. MOUNT. CWH561049 CONDENSER COMPLETE CWB32C1773 EXPANSION VALVE CWB051017J 3-WAYS VALVE(GAS) CWB011295 STRAINER CWB111056 3-WAYS VALVE(LIQUID) CWB011299 RECEIVER CWB141022...

This manual is also suitable for:

Cs-pc36jkf-5Cu-pc30jkf-5Cu-pc36jkf-5

Table of Contents