2.10 EF: PFC fault (Only for 36-56 model)
2.10.1 Digital display output
EF
2.10.2 Description
PFC fault protection.
The system stops running.
Error code is displayed on the outdoor unit PCB.
2.10.3 Trigger / recover condition
Trigger condition:
DC bus
Recover condition:
DC bus
Reset method: Manually restart.
2.10.4 Possible causes
DC fan motor damaged.
Main PCB damaged.
2.10.5 Procedure
Detect the 220V power supply input port to
see whether the voltage is stable
Power off for 3 minutes and then repower on
Check whether fault is cleared
Outdoor unit main control board damaged
60
voltage is over 450V for continue 3 S or over 500V in the first 5 s in PFC star period.
voltage is normal in the first 5 s in PFC star period.
EF
No
No
Waiting for 220V power supply
No
Yes
Power supply is abnormal
stable