Page 1
950L GAS FIRE USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS It is a regula on that these instruc ons be handed to the customer a er installa on is complete. It is also the responsibility of the installa on engineer to ensure that the customer is able to fully operate the appliance and is aware of any cleaning or maintenance requirements.
CONTENTS Regulatory Informa on and Installa on Requirements …………………….. ……. 3 Installa on Requirements (con nued) ……………………………………………….….. 4 Methods of Installa on ………………………………………………………………………….. 5 Mantel Cri cal Dimensions ……………………………………………………………………. 8 Marble Access Cover Dimensions …………………………………………………………... 10 Si ng the Appliance ………………………………………………………………………….……. 11 Fixing the Precast Spacer ……………………………………………………………………..…...
REGULATORY INFORMATION AND INSTALLATION REQUIREMENTS THE FOLLOWING MUST BE NOTED PRIOR TO THE INSTALLATION OF THIS APPLIANCE. This gas appliance MUST be installed by a GAS SAFE registered installer by law. It must be installed in accordance to these installa on instruc ons and the GAS SAFETY (Installa on & Use) REGULATIONS 1998 as amended.
No purpose made ven la on is normally required for this appliance when installed in G.B. If the appliance is being installed in I.E then refer to I.S 813:1996 (Domes c Gas Installa on—Na onal Standards Authority of Ireland). Ven la on areas (if applicable) should be checked periodically to ensure there is no obstruc on, even though none is normally required for this appliance.
INSTALLATION TYPE A These diagrams detail the installa on of the appliance into a standard 16” x 22” opening. This method of installa on is suitable for both Class 1 and Class 2 installa ons. This installa on requires a 950L STANDARD MANTEL. For cri cal dimensions see page 8. The 950L FIXING PLATE supplied is firmly a ached to the builders opening a er the hearth has been installed.
Page 6
INSTALLATION TYPE B These diagrams detail the installa on of the appliance into a Pre Cast Flue block and a 950L STANDARD MANTEL is being fi ed. For details on 950L STANDARD MANTEL cri cal dimensions see page 8 The 950L PRECAST SPACER KIT is used to create an interface between the precast flue and the 950L FIXING PLATE.
Page 7
INSTALLATION TYPE C These diagrams detail the installa on of the appliance into a Pre Cast Flue where a 950L PRECAST MANTEL is being fi ed For details on 950L PRECAST MANTEL cri cal dimensions see page 9. The 950L PRECAST SPACER KIT is used to create an interface between the precast flue and the 950L FIXING PLATE.
950L STANDARD MANTEL CRITICAL DIMENSIONS This Mantel MUST be constructed from Non-Combus ble Materials. These diagrams detail the CRITICAL dimensions which must be achieved for correct installa on of the appliance when being installed into a 950L STANDARD MANTEL.. NOTE: Front Lower Marble Access Plate Dimensions and installa on for BOTH 950L STANDARD &...
Page 9
950L PRECAST MANTEL CRITICAL DIMENSIONS This Mantel MUST be constructed from Non-Combus ble Materials. These diagrams detail the CRITICAL dimensions which must be achieved for correct installa on of the appliance when being installed into a 950L PRECAST MANTEL NOTE: Front Lower Marble Access Plate Dimensions and installa on for BOTH 950L STANDARD &...
MARBLE ACCESS COVER CRITICAL DIMENSIONS This Access Cover MUST be constructed from Non-Combus ble Materials. These diagrams detail the CRITICAL dimensions of the MARBLE/STONE ACCESS COVER This informa on is to be used for both 950L STANDARD & 950L PRECAST MANTELS mm (min) mm (max) DESCRIPTION...
SITING THE APPLIANCE Fireplace Opening IMPORTANT NOTE: This appliance DOES NOT seal onto a marble or stone back panel. The fire is installed directly into the FIXING PLATE assembly. Installa on of this fixing plate is detailed on the preceding pages 5,6 & 7. The mantel should be constructed to the requirements shown on the preceding pages 8,9 &...
Checking the Flue Use a smoke pellet prior to the appliance installa on to ensure the viability of the flue and check that the smoke can be seen being emi ed from the terminal / chimney pot outside. There must be no leakage of smoke through the structure of the chimney/flue during or a er the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney/ flue.
INSTALLING THE FIXING PLATE (PRECAST INSTALLATIONS ONLY ) For Class 1 and Class 2 installa ons see page 14. PRECAST INSTALLATIONS Installing the FIXING PLATE The FIXING PLATE can now be screwed to the PRECAST SPACER. Use the 8 screws supplied with the PRECAST SPACER kit to secure as shown above. Once screwed into posi on ensure this FIXING PLATE is sealed air ght against the PRECAST SPACER with a suitable heatproof silicone externally around the frame and internally around the fireplace opening using fire cement or other suitable non combus ble fondant...
INSTALLING THE FIXING PLATE (STANDARD INSTALLATIONS ) STANDARD INSTALLATIONS Installing the FIXING PLATE The FIXING PLATE can now be screwed to the wall symmetrically around the fireplace opening and hearth. Use the 8 screws and plugs supplied in the appliance installa on kit. Once screwed into posi on ensure this FIXING PLATE is sealed air ght against the wall with a suitable heatproof silicone externally around the frame and internally around the fireplace opening using fire cement or other suitable non combus ble fondant as you would installing...
INSTALLING THE MANTEL (ALL INSTALLATIONS ) Installing the MANTEL The mantel should be placed symmetrically around the FIXING PLATE . Carefully measure the distance between the mantel opening and the front edge of the FIXING PLATE to double check. Failure to fit the mantel in the correct posi on will prevent the front trim assembly from fi...
INSTALLING THE APPLIANCE AS HIW (Hole In the Wall) THIS APPLIANCE CAN BE INSTALLED AS A HOLE IN THE WALL INSTALLATION. FULL DETAILS OF THIS TYPE OF INSTALLATION ARE SUPPLIED WITH THE HIW INSTALLATION KIT (Check with your retailer for availability prior to purchasing appliance). THE INSTALLER MUST INFORM THE USER OF THE FOLLOWING IMPORTANT NOTICES AFTER A HOLE IN THE WALL INSTALLATION HAS BEEN UNDERTAKEN.
GLASS PANEL / FRONT TRIM INSTALLATION Removal and replacement of the front glass panel. The glass panel is held in place with 11 screws. When removing the screws it is advised to remove the bo om 3 white screws first, then the 6 black side screws, and finally the top 2 black screws.
Install the ceramics into the appliance according to these instruc ons—see pages 24 through to 27. Refit the glass panel and front trim cover—See page 17 Test the opera ng pressure of the appliance by a aching a pressure gauge to the test point of the appliance. This connec on should take place when the appliance is OFF.
COMPLETING THE INSTALLATION THE INSTALLER MUST INFORM THE CUSTOMER OF THE FOLLOWING TO COMPLETE THE INSTALLATION Demonstrate the ligh ng of the appliance and the controls to select the heat se ngs. Demonstrate how to ex nguish the fire. Demonstrate the removal of the trim and marble access cover and how to reinstall correctly. Demonstrate the loca on of the ba ery igniter and how to replace the ba ery.
Appliance Technical Informa on Gas Type : Natural Gas Category : I2H Inlet Pressure: (Cold) 20mbar Heat Input Gross : 6.9kW Injector : 080 Des na on Countries : GB Efficiency Class: 1 NOx Class: 5 Efficiency Net: 75.3% HEALTH AND SAFETY NOTICE This appliance uses fuel effect pieces manufactured from Refractory Ceramic Fibres (RCF).
SERVICING THE APPLIANCE The following procedures can and should only be performed by a GAS SAFE registered installer. This appliance should be serviced annually by a GAS SAFE registered installer. Removal / Replacement of Gas Carrying Components. The removal and replacement of all the gas carrying components will require the removal of the burner tray. The following informa on details the removal of this tray.
Page 22
Removal / Replacement of Gas Carrying Components (con nued) Slide Control Valve Remove the locknut from the front of the valve. Undo the three (3) nuts around the periphery of the valve body—Gas Inlet / Burner / Pilot. Remove the thermocouple nut from the back of the valve. The valve can be removed and serviced / replaced as necessary.
OPERATING INSTRUCTIONS SLIDE CONTROL OPERATION Push the control lever to the le to the IGN symbol . The spark generator should cause a repe ve spark at the pilot and the pilot and main burner should ignite. If the pilot does not light a er 10 seconds then slide the control lever to the right towards the OFF symbol and wait for 3 minutes.
FUEL BED LAYOUT The following instruc ons detail how the volcanic rock, ceramic fuel bed and loose components are to be installed onto the appliance. Great care should be taken when handling these ceramic parts as they are fragile and can easily be broken. Do not force any component into posi on, if it does not fit easily then you are not fi...
Page 25
Step 4 Fit front rail (LH and RH) sec ons onto the front support as shown in the picture below. Step 5 Fit Central Log C onto the fuel bed as shown in the picture below.
Page 26
Step 6 Fit ‘Y’ shaped log D onto the fuel bed as shown in the picture below. Step 7 Fit ‘Y’ shaped Log E onto the fuel bed as shown in the picture below.
Page 27
Step 8 Fit Log F onto the fuel bed as shown in the picture below. Step 9 Fit Log G onto the fuel bed as shown in the picture below. Now refit the glass panel, front trim and marble access cover—see page 17 for details...
Product Fiche Manufacturer : Be Modern Ltd Model No. BM-091XX2 Fuel Type Natural Gas I2H Energy Efficiency Class Indirect Hea ng Func onality Direct Heat Output kW 4.6kW Indirect Heat Output kW Useful Energy Efficiency (NCV) High : 75.3% Useful Energy Efficiency (NCV) Nominal Heat Output High : 4.6kW Nominal Heat Output...
APPLIANCE COMMISSIONING CHECKLIST It is the installers responsibility to complete the following checklist when commissioning this appliance. The informa on recorded on this page may be requested at the me of any warranty call made. If the informa on is not made available it may affect the warranty support for the customers appliance.
Tel: 0191 489 8006 Fax: 0191 580 0085 Email: sales@bemodern.com Due to our policy of con nual product improvement, some diagrams and small details may not be accurate however if there is any concern or ma er of understanding that you feel needs to be clarified please contact us directly. Our contact details are shown above.