Keep last value
Keep the counted values when the device powers off.
when power off
Make the device start/stop counting.
Start/Stop
Note: IOT-C50x will send non-changablecounting values if you do not click
"Start".
Refresh
Refresh to get latest counter values.
Clear
Count the value from 0.
4.3.4 AI Settings
1. Connect analog device to analog input ports on interface 1. If you need IOT-C50x to power the
analog device, connect the power cable of analog device to power output on interface 1.
2. Go to "General ->AI" of ToolBox software or "Setting ->AI Setting" to enable analog input
and select the analog type.
Note:
Ensure
DIP switches
3. Enable "Interface 1 (Pin 1) 5V/9V/12V Output" or "Interface 1 (Pin 2) 3.3V Output" and
configure "Power Output Time Before Collect", IOT-C50xwill power the analog devices for a period
of time before collecting data.
Note: When you use power output to power analog devices, it only supplies power when
reporting interval is coming. Itʼs suggested to power slave devices with external power during
the PoC test.
has changed if you need to use 0-10Vmode.
19