LINOVISION IOT-C300-LORA Quick Start Manual

Iot controller

Advertisement

Quick Links

IOT-C300-LORA
IOT Controller
Quick Start Guide
Updated on May18,2022

Advertisement

Table of Contents
loading

Summary of Contents for LINOVISION IOT-C300-LORA

  • Page 1 IOT-C300-LORA IOT Controller Quick Start Guide Updated on May18,2022...
  • Page 2 Safety Precautions Linovision will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. The device must not be remodeled in any way. ❖ ❖ Do not place the device close to objects with naked flames.
  • Page 3: Table Of Contents

    Contents 1. Product Introduction ............................. 4 1.1Overview ............................... 4 1.2Features ..............................4 2. HardwareIntroduction...........................4 2.1Packing List ............................4 2.2HardwareOverview ..........................5 2.3ApplicationWiring..........................5 2.4LED Indicators ............................ 6 2.5Reset Button............................7 2.6Dimensions(mm) ..........................7 3. HardwareInstallation........................... 7 3.1AntennaInstallation..........................7 3.2DeviceInstallation..........................8 3.2.1Wall Mounting.......................... 8 3.2.2DIN Rail Mounting........................8 4.
  • Page 4: Product Introduction

    Industrial metal case design with wide operating temperature range ® Compliant with standard LoRaWAN gateways and network servers ● ● Quick and easy management with Linovision IoT Cloud solution 2. HardwareIntroduction 2.1 Packing List 1 ×IOT-300-LORA 1 ×LoRa 1 ×...
  • Page 5: Hardwareoverview

    1 × 1 ×Warranty Quick Start Guide Card If any of the above items is missing or damaged, please contact your sales representative. 2.2 Hardware Overview 2.3 Application Wiring...
  • Page 6: Led Indicators

    RS485 Terminal Resistor: DIP Switch Description 1 on 2 off 3 off Add 120 Ω resistor between A and B 1 off 2 on 3 off Add pull-downresistor on B 1 off 2 off 3 on Add pull-upresistor on A 2.4 LED Indicators Indication Status...
  • Page 7: Reset Button

    2.5 Reset Button There is reset button inside the device. Description Function SYS LED Action Static Green Press and hold the reset buttonfor more than 10 seconds. Static Green → Reset Release the button and wait. Rapidly Blinking Off → Static Green The device resets to factory default.
  • Page 8: Deviceinstallation

    3.2 Device Installation IOT-300-LORA device can be placed on a desktop or mountedto a wall or a DIN rail. 3.2.1 Wall Mounting 1. Fix the wall mountingbracket to the device with 2 screws. 2. Drill 4 holes on the wall according to the bracket, then fix the wall plugs into the wall. 3.
  • Page 9: Operationguide

    2. Hang the device to the DIN rail. The width of DIN rail is 3.5cm. 4. Operation Guide 4.1 Log in the ToolBox 1. Download ToolBox software from Linovision website. 2. Power on the IOT-300-LORA device, then connect it to computer via type-C port.
  • Page 10 3. Open the ToolBox and select type as “General”, then click password to log in ToolBox. (Default password: 123456) 4. After logging in the ToolBox, you can change device settings.
  • Page 11: Communicationsettings

    4.2 CommunicationSettings 4.2.1 LoRaWAN Settings (LoRaWAN Version Only ® LoRaWAN settings is used for configuring the transmission parameters in LoRaWAN network and is only appliedto version. Basic LoRaWAN Settings: Go to “LoRaWAN Settings -> Basic” to configure join type, App EUI, App Key and other information.
  • Page 12 1) Please contact sales for device EUI list if there are many units. 2) Please contact sales if you need random App keys before purchasing. 3) Select OTAA mode if you use Linovision IoT Cloud to manage devices. 4) Only OTAA mode supports rejoin mode.
  • Page 13: Data Interfacesettings

    If frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box,making them separated by commas. Examples: 1, 40: Enabling Channel 1 and Channel 40 1-40:Enabling Channel 1 to Channel 40 1-40,60:Enabling Channel 1 to Channel 40 and Channel 60 All: Enabling all channels Null: Indicates that all channels are disabled...
  • Page 14: 2Digitalinput/Pulsesettings

    Parameters Description Device ID Show the SN of the device. Reporting interval of transmitting data to network server.Default: 20mins Reporting Interval Note: RS232 transmission will not follow the reportinginterval. See details on chapter 4. 5. LoRa D2D Change Password Change the password to loggin ToolBox. 4.3.2 Digital Input/PulseSettings IOT-C300-LoRaWAN ®...
  • Page 15: 3Digitaloutputsettings

    Parameters Description Enable Enable digital input to detect status and upload the data. Digital Input Fetch Click to get the current inputstatus. Counter Digital Filter Itʼs recommended to enable when pulse period is greater than 250 us. Click to start/stop counting. Note that IOT-C300-LoRaWAN ®...
  • Page 16 1200/2400/4800/9600/19200/38400/57600/115200are available. Execution Interval The execution interval between each Modbus channel command. (ms) The maximum response time that the IOT-C300-LORA waits for the Max Resp Time reply to the command. If it does not get a response after the max (ms) response time, it is determined that the command has timed out.
  • Page 17: 5Rs232Settings

    Example: as this setting, the device will send command: 01 03 00 00 00 01 84 0A Fetch 4. Click “Fetch” to check if IOT-C300-LORA can read correct data from terminal devices. Note: Do not click “Fetch” frequently since response time to reply is differ for every terminal device.
  • Page 18 Parameters Description Baud Rate 1200/2400/4800/9600/19200/38400/57600/115200are available. Data Bit 8 bit is available. Stop Bit 1 bit/2bit are available. Parity None, Odd and Oven are available. Packet Length When the device receives RS232 data up to this length, it will fragment it as (byte) a single packet and send to network server.
  • Page 19: 6Analog/Pt100Settings

    Show the connection status between the device and the TCP server. 4.3.6 Analog/PT100Settings IOT-C300-LORA has two 4-20mAanalog inputs, two 0-10Vanalog inputs and two PT100 inputs for analog device connection. After wirings, you can click “Fetch” to check if the value is correct.
  • Page 20: If-Thencommand

    4.4 IF-THEN Command IOT-C300-LORA supports configuring locally IF-THEN commands to do some actions automatically even without network connection. One device can be added 16 commands at most. 1. Go to “Command” page, click “Edit” to add commands.
  • Page 21 2. Set a IF conditionbased on the terminal device data or IOT-C300-LORA device status. Condition Description Set the time condition. The device time will be synced once after Time joining/registeringto network, you can also sync the time manually on “Status”...
  • Page 22 When the value reaches any threshold. Is continuedfor: the analog value should last for some time. Set lockout time: after the lockout time, IOT-C300-LORA device will detect Channel/4-20m if analog value matches the condition. 0 means this IF condition will only be detected once.
  • Page 23: Lora D2Dsettings (Lorawan Versiononly)

    LoRa D2D protocol is developed by Linovision and used for setting up transmission among Linovision devices without gateway. When the LoRa D2D setting is enabled, IOT-300 can work as a LoRa D2D controller to send control commands to other devices or work as a LoRa D2D agent to receive commands to trigger the DO or RS485 devices.
  • Page 24 LoRa D2D agent device. The command should be a 2-bytehexadecimal number. When IOT-C300-LORA receives a LoRa D2D command, it can work as a LoRa D2D agent to trigger the DOor send Modbus command to RS485 terminal devices.
  • Page 25: Maintenance

    4.6.1 Upgrade IOT-C300 supports upgrade locally via ToolBox software. 1. Download firmware from www.linovision.com to your PC. 2. Go to “Maintenance ->Upgrade”,click “Browse” to import firmware and upgrade the device. You can also click “Up to Date”to search for the latest firmware of the device and upgrade.
  • Page 26: 2Backup

    4.6.2 Backup IOT-300 devices support configurationbackup for easy and quick device configuration in bulk.Backup is allowed only for devices with the same model and LoRa frequency band. 1. Go to “Maintenance ->Backup and Reset”, click “Export” to save current configuration as json format backup file.
  • Page 27: Devicepayload

    5. Device Payload For IOT-300 LoRaWAN version,please refer to the IOT-300 LoRaWAN Communication ® Protocol; For IOT-300 cellular version, please refer to the IOT-300 Cellular Communication Protocol; for decoders of Linovision IoT products please click here. -END-...

Table of Contents