Chapter 2 – AC 80 Hardware and Connections
AC 80 Connections
Terminal
Name
(see above)
Power
L+ L+ SA
Supply
L– L– SB
AF 100
AF100 1
AF100 2
Service
Ch1
(Terminal
Board X4)
Panel/Printer
Ch2
(Terminal
Board X5)
1
Battery
2
Tool*
(NCB CH3)
3
DriveBus*
(NCB CH0)
4
Special I/O*
(NCB CH1)
5
Fieldbus
Adapter*
(NCB CH2)
6
Optical
ModuleBus
(optional)*
7
Electrical
ModuleBus
2-6
1
Ch2
Ch1
L+ L+ SA
1
AF100
2
+
SH
SH
L– L– SB
For connection of
Power Supply
0.2 to 2.5 mm
AF 100 (Advant
Screened twisted
Fieldbus 100)
pair
PC (Configuration
RS-232
and Maintenance)
CDP 80 Ctrl. Panel
RS-485
Alarm printer
GOP Panel
Battery
PC tools
Fibre optic
(Drive Debug )
ABB drives
Fibre optic
Branching units
NBIO-21, NBIO-31,
Fibre optic
NPCT-01, DSU
Fieldbus Adapters,
Fibre optic
e.g. NPBA-80
TB820 Modems
Fibre optic
ABB drives
S800 I/O units
C/4 Plug-in
*Colour codes: Grey: Transmitter, Blue: Receiver.
7
5 6
2
4
3
7
2
8
Tx
1
9
0
5 6
Rx
4
7
3
2
8
1
9
0
3
4
5
+
Tx
6
SH
Rx
SH
Cable
2
+24 V d.c.
(19.2 to 30 V)
Max. length 750 m
Max. no. of nodes 32
RS-232 signal levels
Max. comm. 20 kbit/s
Protocol: Modbus
RS-485 signal levels
Max. comm. TBD
Lithium 3.6 V 900 mAh
Protocol: DDCS
Protocol: DDCS,
DDCSe
Protocol: DDCS
Protocol: DDCS
Protocol: DDCS
Max. 12 I/O units in
max. 7 clusters
Max. 12 I/O units
24 V supply 1.0 A
5 V supply 2 A
Data
Remark
Redundancy
available
Redundancy
available
D-sub
9-pole
D-sub
15-pole
14.5 × 25 mm
10 MBd optical
components
10 MBd optical
components
5 MBd optical
components
5 MBd optical
components
Requires
TB810/811
Optical Port
AC 80 User's Manual