Special Precautions; Water Connection; Water Draining System - Electrolux 6 GN 1/1 Installation And Operating Manual

Gas heated convection ovens
Table of Contents

Advertisement

2. Lift the appliance with a lift truck, remove the base;
20 GN
5 1 " 130 mm
8
6-10 GN
3. Position it the place of use;
4. Remove the protective film;
Make sure the packing material is not dispersed in the
environment but disposed of according to the current regu-
lations in the country where the product is used.
G.1.1
For the overall space required and connection dimensions,
refer to the installation diagrams;
• Refer to the installation diagrams at the beginning of this
handbook for the appliance's overall dimensions and
connections.
• The left side of the appliance must remain at least 500 mm
from other surfaces to enable maintenance operations
while the right side must be installed 100 mm from surfaces
made from flammable materials.
• Position the appliance on a flat surface.
• If necessary, adjust the height of the worktop by means of
the adjustable feet.
G.2
6-10 GN
Refer to the installation diagrams at the beginning of this
handbook.
• Fit a mechanical filter and shut-off tap between water inlet
pipe "C" and the mains water supply.
• Before connecting the filter, run off a certain amount of
water to remove any ferrous particles from the piping.
• The water inlet must be connected to a drinking water
supply with pressure of 150 – 250 kPa (1.5 – 2.5 bar / 22 –
36 psi).
G.2.1
• Connect drain fitting "C" to a drain pipe of the same
diameter which is between 0.5 and 3 metres in length and
is resistant to temperatures of at least 100℃.
20 GN

Special precautions

NOTE!
The appliance is not suitable for built-in installation.

Water connection

IMPORTANT
When connecting the appliance with the flexible
hoses to the water system, use always new ones.

Water draining system

O
20 GN
6-10 GN
AIR-BREAK
C
min 5°
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

10 gn 1/110 gn 2/120 gn 2/1

Table of Contents