Preparing The Mounting Cutout - Siemens SIMATIC IPC377G Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC377G:
Table of Contents

Advertisement

• Vertical installation in upright format, display turned through ±90 ° compared with the
standard position
For vertical installation in upright format, the following ambient temperatures are
permitted:
3.1.4

Preparing the mounting cutout

Note
Stability of the mounting cutout
The material in the area of the mounting cutout must provide sufficient strength to
guarantee the enduring and safe mounting of the device.
To achieve the degrees of protection described below, it must be ensured that deformation of
the material cannot occur due to the force of the mounting clips or operation of the device.
Degrees of protection
The degrees of protection of the device can only be guaranteed if the following requirements
are met:
• In order to achieve IP65 protection degree, the material thickness for the mounting cutout
should be: 2 mm to 6 mm
• Permissible deviation from plane at the mounting cutout: ≤ 0.5 mm
This condition must be fulfilled for the mounted device.
• Permissible surface roughness in the area of the seal: ≤ 120 µm (R
SIMATIC IPC377G
Operating Instructions, 07/2022, A5E51366314-AB
Maximum ambient temperature at the device
12" and15"
50 °C
19" and 22"
45 °C
The device enclosure fulfills the requirement of
a fire protection enclosure (see "General safety
instructions (Page 15)").
Installing and connecting the device
3.1 Preparing for installation
Comment
120)
z
23

Advertisement

Table of Contents
loading

Table of Contents