Troubleshooting; Alarm Register; Maintenance; Battery - Xylem Sensus Domo R Instructions For Installation, Use And Maintenance Manual

Wm-bus module
Table of Contents

Advertisement

3.4 Troubleshooting

Fault
The radio module is not
transmitting
The LED of the radio
module does not light
up during installation
4. Alarms register
The two-byte value of the error flag is shown in the table below. Please note that the first and the second byte represent the very same error, in
the so called "IS" and "WAS" flavour, with "IS" meaning that the alarm/error is currently present, while "WAS" meaning it was present at some time
in the past.
b0
Mechanical Fraud IS
b1
Magnetic Fraud IS
b2
Suspected Leakage IS
b3
Backflow IS
b4
Overflow IS
b5
Meter Reversed IS
b6
No Consumption IS
b7
Reserved
b8
Mechanical Fraud WAS
b9
Magnetic Fraud WAS
b10
Suspected Leakage WAS
b11
Backflow WAS
b12
Overflow WAS
b13
Meter Reversed WAS
b14
No Consumption WAS
b15
Not Used

5. Maintenance

5.1 Battery

The radio module is equipped with a 3.0 V lithium manganese battery that is not rechargeable but can be replaced. The typical lifespan of the
battery is 11 years, calculated using factory set-up (mode T1, short frame: one message every two minutes)
• between -10 °C and +0 °C for 10% of lifespan
• between 0 °C and +30 °C for 80% of lifespan
• between +31 °C and +55 °C for 10% of lifespan
Warning
Humidity and intense heat may damage the battery and reduce its lifespan.
The radio module calculates the residual lifespan of the battery on the basis of stored parameters, such as estimated consumption
of the electronic board in stand-by mode, transmitter consumption and number of transmissions performed. Battery life depends largely on the
frequency of data transmission set.
Danger
If the battery is empty, it is necessary to contact the metering operator for the correct replacement procedure. The battery must be
disposed of in compliance with applicable laws on waste disposal in the country of installation.
Cause
Electrical or electronic devices interfere with the
signal
Battery empty
Mechanical fraud alarm active
Fixing screw stripped
Faulty module
Mechanical fraud alarm active
Solution
Move devices to a sufficient distance away
Move the receiver closer
Replace the battery (contact the metering operator)
Contact the metering operator
Contact the metering operator
Contact the metering operator
Contact the metering operator
Radio Evo is removed from the meter now
A fraud with a magnet is detected now
A leakage could be present now
Reverse water flow exceeds the maximum threshold now
Maximum flow rate is exceeded now
Meter could be mounted in the wrong verse
Meter could show no water consumption now
Reserved
Domo R was removed from the meter in the past
A fraud with a magnet was detected in the past
A leakage could have been present in the past
Reverse water flow exceeded the maximum threshold in the past
Maximum flow rate was exceeded in the past
Meter could have been mounted in the wrong verse in the past
Meter could have shown no water consumption in the past
Bit not used