7.3.2.2

Operational Steps

To initiate an automatic charge cycle, one assumes that a fully discharged battery (V
inserted.
Also the TA needs to be inserted to J1 – there is no order in which the battery or TA needs to be
inserted first.
In addition, J60 must be connected to the USB port of a computer for I2C communication using the
DA9318 Reference Board
NOTE
Reference Designator
Position
Close
J15
Open
J16
NA
Close
J18
Open
J19
NA
Both jumpers on J15 and J18 must not be fitted. The battery +/- senses must be connected to J16 (+ sense) and
J19 (- sense).
The steps to operate the automatic charge cycle are highlighted in
1. Check out the battery charge voltage (see battery information) and set the Main CV accordingly.
2. As required, check out and modify the Auto Charging parameters in the Options → Settings
window – see paragraph 7.3.2.1.
3. Click the Auto Charge button, to start the automatic charge cycle.
The charge cycle (i.e. plotting the battery voltage and charge current) is shown by the Profile Plot of
the Real-time Charging Performance Graphs.
The main charger and DA9318 efficiency is shown by the Efficiency Plot; whereas the DA9318 die
temperature is shown by the Temperature Plot.
2
3
Figure 33: GUI Configuration – Automatic Charge Operation
User Manual
CFR0012
SmartCanvas
GUI software.
Function
Short VOUT_DA9318 to VBATP for a local pack sensing
VOUT_DA9318 and VBATP disconnected to allow cell sensing
VBATP connector for cell sensing
Short GND to VBATN for a local pack sensing
GND and VBATN disconnected to allow cell sensing
VBATN connector for cell sensing
1
Revision 3.2
32 of 39
< 2.8 V) is
BAT
Figure
33:
16-Feb-2022
© 2022 Renesas Electronics