DA9318 Direct Charging Reference Board
6. When the TA CC Setting has reached the minimum value, disable the Direct Charger switch to
return to main charger until the DONE status indicator flags green, signaling the end of the
charge cycle.
NOTE
Unless the watchdog timer is serviced, it is recommended to disable it by disabling the Chgr Watchdog switch
while the main charger is enabled.
This is to ensure that the main charger does not initiate a power-on-reset when the watchdog timer has expired.
Indeed, when the watchdog timer has expired, the device returns to default mode and all registers are reset to
default values.
When highlighted, clicking on the Clear Events switch clears all DA9318 events. When no events are flagged
the switch indicates No Events.