Inspection And Service - Aqua Lung MEER LW User Manual

Maritime emergency egress rescue
Table of Contents

Advertisement

INSPECTION AND SERVICE

1. It cannot be assumed that MEER is in good working order on the basis that it has
received little use since it was last serviced. Remember that prolonged or improper
storage can still result in internal corrosion and/or deterioration of o-ring seals and
valve springs.
2. It is imperative that manufacturer prescribed service on MEER is performed by a
manufacturer trained service technician according to the procedures outlined in our
Technical Manual once every two years under normal prescribed use OR once a year
if operating in an environment where harsh / heavy / in-water or training use may exist.
Manufacturer prescribed service consists of:
Complete overhaul of the first and second stage regulator.
Visual inspection of the cylinder in accordance with local regulatory
requirements.
Verification of current hydrostatic test date on cylinder. Re-test of cylinder in
accordance with local regulatory requirements.
Verification of cylinder end of life date. Cylinder must be replaced upon
expiration of this date.
3. DO NOT attempt to perform any disassembly or service to MEER. Doing so may cause
MEER to dangerously malfunction. All service must be performed by a manufacturer
trained service technician.
17