AP0647
300 bar Fill Adapter
NOTE: MEER does not include a HP fill adapter. The 300 bar fill adapter is
available to be purchased separately. (Fig. 5).
CAUTION:
the fill port and cylinder pressure rating.
CAUTION:
station unless you have received the necessary training and authorization
to do so. If done incorrectly, this procedure poses certain hazards which
may cause severe injury or death.
CAUTION:
to indicate accurate cylinder filling pressure.
WARNING:
a compressor or air supply where the regulated pressure exceeds the
cylinders maximum fill pressure. Doing so could cause a dangerous
malfunction to the fill adapter, resulting in serious injury or death.
6. Inspect the fill adapter to ensure that the o-ring
is present, not damaged and seated evenly at the
base of the threads. Check the threads of the male
fitting, making sure they are clean and not damaged.
7. Insert the threaded male fitting of the fill adapter
into the fill port on the first stage. Screw the
adapter into the fill port until finger-tight. DO NOT
apply a wrench or otherwise overtighten the fill
adapter (Fig. 6).
Ensure that the pressure rating on the HP fill adapter matches
Do not attempt to fill MEER directly from a compressed air filling
The dial indicator is for reference only. Use the fill system gauge
DO NOT attempt to use the HP fill adapter to fill MEER from
O-Ring
Figure 5
Fill
Adapter
Figure 6