Refrigerator Air Channel

Remove the Air Flow Channel
1. Remove the two screw covers and the screws
behind them (1 at each end of the center shelf
support).
a
a
Shelf support screws (2)
b
Center shelf support
2. Remove four screws from the chilled water tank
cover.
a
a
Water tank screws (4)
3. Remove lower cover by pulling it from either
corner.
NOTE: The center glue strip seal on the air duct
will offer resistance.
b
36
4. Unplug damper and temp sensor connections.
a
a
Chilled water tank
b
Air duct
c
Damper connection
d
Temp sensor connection
5. Pull on the air duct from either side to unsnap
it from the back wall.
NOTE: The damper is in the base of the air duct
just under the foam cover.
a
b
a
Temp sensor
b
Air duct base
b
c d