Remove the Condenser Fan Motor and
Defrost Drain Tube
1. Remove machine compartment cover.
a
Machine compartment cover
2. Remove screw in bottom of condenser fan
frame.
3. Remove fan plug in ceiling of machine
compartment.
a
a
Fan plug
b
Fan frame
c
Condenser fan frame screw
a
b
c
4. Remove fan frame by sliding it straight toward
you to access evaporator drain tube. Make sure
the drain tube is positioned, as shown.
NOTE: The channels that hold the fan frame. To
reassemble, slide the fan frame into these two
channels.
a
a
Fan frame channels (2)
b
Evaporator drain tube
5. Release the fan motor from the four snaps
securing it in the housing.