Interior Lights - Hisense HRF266N6CSE Service Manual

Hide thumbs Also See for HRF266N6CSE:
Table of Contents

Advertisement

Interior Lights

Rated Voltage: DC12V
Check the Light
Mainboard Wiring Connection
1. Make sure the wiring connections between
the light and mainboard are secure. If wiring
connection is loose, repair connection.
Refrigerator Light 1: Corresponds to Pins No. 1
and No. 2 on CN7 connector on the mainboard.
Freezer Light: Corresponds to Pins No. 1 and
No. 3 on CN7 connector on the mainboard.
Check Output Voltage
Using a multimeter,
check the voltage output of
the pins on the mainboard that correspond with
the non-working light.
If the voltage measures 12V, the mainboard is
good. Replace the light.
OR
If the voltage does not measure 12V, replace the
mainboard.
Remove LED - Refrigerator Compartment
1. Unplug the refrigerator or disconnect power.
2. Using a flat-blade screwdriver or putty knife,
pry up on the light cover to release it from the
clips.
3. Remove the light.
38