Chapter 1
1.1 Making Pre-Checks
1.1.1 Selecting the Site
The site must meet the following requirements; if possible, visit the user's before
the machine is delivered:
1.
2.
3.
4.
5.
6.
2
The site must offer a power outlet whose rating is as specified volts (-/
+10%) and which may be used exclusively for the machine.
The site temperature must be between 0 deg and 35 deg C (32 deg and 95
deg F) and between 35% and 85% humidity. Avoid an area near a water
faucet, water boiler, humidifier, and refrigerator.
The site must not be near a source of fire, or must not be subject to dust
or ammonium gas. Also, avoid areas exposed to direct rays of the sun; if
necessary, provide curtains.
The level of ozone generated by the machine while in use will not affect
the health of the human body. However, some individuals may find its
odor unpleasant. Be sure to ventilate the room well to provide a good
working environment.
The machine will have to be at least 10cm/3.9" from any wall, offering
enough space for its use.
10cm / 3.9"
50cm / 19.7"
The machine will have to be placed in a well-ventilated area of the room.
Do not, however, place it near the inlet of air.
T-1-1
50cm / 19.7"
0006-2646