Nozzle Table - industro clean WAP NOVASTAR HPC 14/130E Operating And Instruction Manual

Cold water high pressure cleaner
Table of Contents

Advertisement

REF. 10: NOZZLE TABLE
It is imperative to use only the stipulated nozzles with this pump module. Incorrect
nozzle sizes will cause the equipment to malfunction, as the operating pressure
depends on the orifice of the nozzle.
The pressure indications stated in the paragraph "Technical Specifications" and in the
table below can vary slightly due to the following reasons:
- manufacturing tolerances of the nozzle,
- voltage and frequency fluctuations of the power supply.
At this stage, the machine is standard equipped with nozzle reference number "2506",
resulting in a 25° spray angle at 115 bar operating pressure.
HP NOZZLE
HP NOZZLE
(PENCIL JET)
*
COMBI NOZZLE
*
Used only in conjunction with Venturi type low pressure chemical injectors.
TYPE OF NOZZLE
SPRAY ANGLE
15
25
O
O
15065
25065
1506
2506
15055
25055
0006
61037
PRESSURE
BAR
50
O
85
115
130
115 - 120
optional
standard
optional
PAGE NO: 18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wap novastar hpc 14/150e

Table of Contents