REF. 9: HIGH PRESSURE PUMP OIL CHANGE
The oil level of the high pressure pump must be checked periodically and topped-up, as
required.
The high pump is equipped with a sight glass, as well as a dip stick for convenient
measuring.
FIRST OIL CHANGE:
FREQUENCY OF OIL CHANGE:
RECOMMENDED OIL:
IT IS IMPERATIVE TO MONITOR PUMP OIL LEVELS
30 – 50 Hours from commissioning
Approximately every 100 operating hours, or
every second month.
WAP HP PUMP OIL
Ref No: 1700000101 (BLUE LABEL)
Supplied in one litre containers.
Motor oils of the SAE 20/30 grade can also
be used, if the above oil is not available.