Rsa And Service Processor; Rsa Unable To Load Firmware; Rsa/Service Processor Invalid Naming; Light Path Points To Pci Led - IBM eserver Cluster 1350 Installation And Service Manual

Table of Contents

Advertisement

RSA and Service Processor

If there are any Remote Supervisor Adapter (RSA) errors, check to make sure the
RSA is in PCI slot 2.

RSA unable to load firmware

This condition is indicated by error FFFF, 0007. Power cycle the RSA adaptor to
clear this condition. The RSA may need to be replaced if this condition persists.

RSA/Service Processor invalid naming

There cannot be any spaces when assigning names of the RSA and Service
Processor. If a name is not recognized, make sure that there are no trailing blanks
after the name.

Light path points to PCI LED

If Light Path diagnostics points to PCI LED, reseat the PCI boards.

Myrinet communication fails

If communication fails over the Myrinet switch then check the following:
v If the Myricom adapter card green LED light is not on, check the cable connector
v Check to see that the GM module is installed by running the lsmod command.
v Check to see if the Myricom adapter is up and running by using the ifconfig
for correct polarity (transmit/receive).
command.
Appendix D. Known problems