Waterous CM Series Overhaul Instructions page 15

Fire pumps
Hide thumbs Also See for CM Series:
Table of Contents

Advertisement

Safety
Removing the Intake Adapters
1
2
Introduction
3
Disassembly
15 | 70
Assembly
Use the illustrations and instructions to remove the
intake adapters.
Note: Only remove the intake adapters if they or the
pump body need to be replaced.
1
Remove the flap valve, then remove the
bearing from each end of the valve.
2
Remove the mounting hardware, then remove
the intake adapter.
3
Remove and discard the gaskets.
4
Repeat the previous steps to remove the
intake adapter at the other end of the pump.