42
6.5 Damper
6.5.1 Basic parameters
Rated voltage: DC12V
Rated current: 60mA
6.5.2 Checking method
1. Check the connecting wiring of the damper is well or not, repair if it is broken. The
damper corresponding pin No.1~6 on CN6 connector of mainboard, as the drawing below.
2. The damper will turn on and off for one time after power-on, if not, change the
mainboard first and change the damper if problem remains.
6.5.3 Removing the damper
Step 1:Remove the four screws (1) with a Philips screw driver.
Step 2:Remove the bracket cover(2).
Step 3:Remove the two screws (3) holding the fridge air duct with a Philips screwdriver,
and then remove the fixed board (4).
Step 4:Remove the two wire connectors(5).
Step 5: Remove the fridge air duct(6) with your both hands.
Step 6: Rive off the foam strip (7) ,and then remove the wind gate foam(8).
Step 7: Remove the fridge electric wind gate.
Hisense Refrigerator