Technical specifications
Table 3-7
Technical specifications for Power Module (380 V – 480 V 3 AC)
Order number
Rated output current I
N
Base load current I
L
Base load current I
H
Max. output current I
max
Unit rating
1)
Power on basis of I
H
Rated input current
Line supply voltages
- Line voltage
- Line frequency
- Electronics power supply
DC link voltage
Output voltage
Rated pulse frequency
Max. pulse frequency without derating
Max. pulse frequency with derating
Electronics current drain (24 V DC)
Cooling type
Power loss
2)
- Air / Coolant
- Total losses
Max. coolant temperature:
- without derating
- with derating
Cooling air requirement
3)
Liquid volume of integrated heat exchanger
Typ. pressure drop with volumetric flow
Sound pressure level
Line / DC link/motor connection
Max. connection cross-section
Line connection (U1/L1, V1/L2, W1/L3)
DC link connection (DCP, DCN)
Motor connection (U2, V2, W2)
PE connection
Max. cable length
Degree of protection
Dimensions
Width
Height
Depth
Frame size
Weight
UL listed fuse
5)
Number (connected in parallel)
Rated current
Size acc. to DIN 43620-1
Rated output of a typical standard asynchronous motor at 400 V 3 AC.
1)
At rated pulse frequency
2)
This value applies to both coolant options, i.e. water and water / Antifrogen N mixture with 45 %
3)
Antifrogen N.
This value applies to the water coolant option; for other coolant types, see Chapter 8.
4)
In order to build a UL-approved system, it is absolutely essential to use the specified fuses.
5)
3-14
6SL3315–
1TE32-1AA0
A
210
A
205
A
178
A
307
kW
110
kW
90
A
230
V
ACeff
Hz
V
DC
V
DC
V
ACeff
kHz
2
kHz
2
kHz
8
A
1.4
Liquid cooling with integrated stainless steel heat exchanger
kW
0.06 / 2.42
kW
2.48
°C
45
°C
50
l/min
9
dm³
0.52
Pa
70000
4)
dB(A)
52
mm²
2 x 95
mm²
2 x 95
mm²
2 x 95
mm²
2 x 95
m
IP00
mm
265
mm
835.5
mm
549
FL
kg
77
3NE1 230-2
1
315
1
SINAMICS S120 Equipment Manual, Edition 12/2007, 6SL3097-2AM00-0BP4
1TE32–6AA0
260
250
233
375
132
110
285
380 3AC –10 % to 480 3AC +10 % (-15 % < 1 min)
47 to 63 Hz
24 (20.4 – 28.8)
1.35 x U
0 to 0.72 x DC link voltage
2
2
8
1.4
0.07 / 3.04
3.11
45
50
9
0.52
70000
52
Flange connection with screws M12
2 x 95
2 x 95
2 x 95
2 x 95
300 (shielded) / 450 (unshielded)
IP00
265
835.5
549
FL
77
3NE1 331-2
1
350
1
1TE33–1AA0
1TE35–0AA0
310
490
302
477
277
438
453
715
160
250
132
200
340
540
line
2
2
2
2
8
8
1.5
1.5
0.09 / 3.40
0.14 / 5.43
3.49
5.57
45
45
50
50
12
12
0.88
0.88
70000
70000
52
52
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
IP00
IP00
265
265
983
983
549
549
GL
GL
108
108
3NE1 333-2
3NE1 230-2
1
2
450
315
2
1
Chassis Power Units Liquid Cooled