Siemens SINAMICS S120 Equipment Manual page 122

Chassis power units liquid cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules
5.6 Technical specifications
Table 5-8
Technical specifications for the Motor Module, 510 V – 720 V DC (part 2)
Order number
Rated output current I
N
Base load current I
L
Base load current I
H
Max. output current I
max
Unit rating
1)
Power on basis of I
H
Rated DC link current
Connection voltages
- DC link voltage
- Electronics power supply
Output voltage
Rated pulse frequency
Max. pulse frequency without derating
Max. pulse frequency with derating
Electronics current drain (24 V DC)
Cooling type
DC link capacitance
Power loss
2)
- Air / Coolant
- Total losses
Max. coolant temperature:
- without derating
- with derating
Coolant requirement
3)
Liquid volume of integrated heat exchanger
Typ. pressure drop with volumetric flow
Sound pressure level
DC link/motor connection
Max. connection cross-section
DC link connection (DCP, DCN)
Motor connection (U2, V2, W2)
PE connection
Max. cable length
Degree of protection
Dimensions
Width
Height
Depth
Frame size
Weight
UL listed fuse
5)
Number (connected in parallel)
Rated current
Size acc. to DIN 43620-1
Rated output of a typical standard asynchronous motor at 400 V 3 AC.
1)
At rated pulse frequency
2)
This value applies to both coolant options, i.e. water and water / Antifrogen N mixture with 45 %
3)
Antifrogen N.
This value applies to the water coolant option; for other coolant types, see Chapter 8.
4)
In order to build a UL-approved system, it is absolutely essential to use the specified fuses.
5)
5-18
6SL3325–
1TE36-1AA0
A
605
A
590
A
460
A
885
kW
315
kW
250
A
738
V
DC
V
DC
V
ACeff
kHz
1.25
kHz
1.25
kHz
5
A
1.6
Liquid cooling with integrated stainless steel heat exchanger
μF
12600
kW
0.17 / 4.82
kW
4.99
°C
45
°C
50
l/min
16
dm³
0.74
Pa
4)
70000
dB(A)
54
mm²
Busbar
mm²
4 x 240
mm²
2 x 240
m
IP00
mm
265
mm
984
mm
545
HXL
kg
110
3NE3 338-8
1
800
2
SINAMICS S120 Equipment Manual, Edition 12/2007, 6SL3097-2AM00-0BP4
1TE38–4AA0
1TE41-0AA0
840
985
820
960
700
860
1230
1440
450
560
400
450
1025
1202
510 to 720
24 (20.4 – 28.8)
0 to 0.72 x DC link voltage
1.25
1.25
1.25
1.25
5
5
1.6
1.46
17400
21000
0.23 / 5.75
0.48 / 7.94
5.98
8.42
45
45
50
50
16
27
0.74
1.56
70000
70000
56
56
Flange connection with screws M12
Busbar
Busbar
4 x 240
4 x 240
2 x 240
2 x 240
300 (shielded) / 450 (unshielded)
IP00
IP00
265
295
984
1496
545
545
HXL
JXL
110
220
3NE3 335
3NE3 336
2
2
560
630
2
2
Chassis Power Units Liquid Cooled
1TE41–4AA0
1405
1370
1257
2055
800
710
1714
1.25
1.25
5
1.46
29000
0.63 / 10.16
10.79
45
50
27
1.56
70000
56
Busbar
4 x 240
2 x 240
IP00
295
1496
545
JXL
220
3NE3 340-8
2
900
2

Advertisement

Table of Contents
loading

Table of Contents