Modbus Register Table - ICP DAS USA iNS-308 User Manual

8-port 10/100base-tx iot switch
Table of Contents

Advertisement

iNS-308 User Manual

7.3 Modbus Register Table

0xxxx: DO address (Base 0)
Address
CH
00000~00007
8
PoE Enable
PoE CDPL enable
00032
1
Auto Class Define Power Limit
00040
1
Ethernet Jumbo Frame
00041
1
Ethernet Loop Detect
00042
1
Ethernet Broadcast storm filter
 3xxxx: AI address (Base 0)
Address
CH
30000~30007
8
PoE Port Current (mA)
30032~30040
8
PoE Port watt (mW)
30096~30103
8
PoE Port TEMP (°C)
30129~30137
8
PoE Port PD Device Class
30160
1
PoE Port Volt
30192~30200
8
Ethernet Link status
30256
1
Module Name
30257
1
FW version
30258
1
HW version
Copyright © 2022 ICP DAS CO., Ltd. All Rights Reserved.
Description
Description
Range
0=OFF, 1=ON
0=Disable
1=Enable
0=Disable
1=Enable
0=Disable
1=Enable
0=Disable
1=Enable
Range
2-Byte, DEC(mA)
2-Byte, DEC(mW)
2-Byte, DEC(°C)
Detect PD Class 0~4
5 is unknow
2-Byte, DEC(V)
1 =>100M Full
2 =>100M Half
3 =>10M Full
4 =>10M Half
5 =>unlink
2-Byte, Hex 0x0308
2-Byte, Hex
2-Byte, Hex
Access Type
R/W
R/W
R/W
R/W
R/W
Access Type
R
R
R
R
R
R
R
R
R
- 44 -

Advertisement

Table of Contents
loading

Table of Contents