Labnet VorTemp 1550™ shaking incubator is designed to be safe when operated under the following conditions:
Indoor use

Altitude up to 2,000 meters

Pollution Degree 2

Unit can be connected to external installation with overcurrent protective device max. value 16A or 20A (USA/CANADA). This device
is intended for use in a basic electromagnetic environment (Basic, class B), and it is in compliance with IEC 61326-1:2020. Device may
experience a restart during overvoltage events (surges) or voltage interruptions in mains power supply.

3.1. Construction

The housing of Labnet VorTemp 1550 shaking incubator is constructed of steel plate coated with highly resistant polyurethane
lacquer. The interior chamber is isolated with special thermal protection materials and insulation foam. Both the shaking mechanism
and temperature chamber regulated via microprocessors, which control all sensors for motor speed, temperature, and time.

3.2. Main Components

Drive motor

Eccentricity control mechanism chamber

Fan

Heating element

Temperature sensor

Temperature controlled chamber control

Electronics

The motor drives the eccentricity control mechanism chamber which generates the orbital motion of the sample platform.
The motion of the motor also drives the fan, which moves air over the heating element and throughout the temperature chamber. The
convection action of the airflow creates a very uniform temperature environment throughout the chamber. Chamber conditions are
monitored by the temperature sensor and the control electronics regulate heater function to maintain the set temperature.

4.0 Accessories

Cat. No.
Description
S2056-R
1.5/2.0 mL platform/workstation for microcentrifuge tubes
S2056-Q
Microplate platform
C1205
Individual adapters for 0.5/0.6 mL tubes
C1206
Individual adapters for 0.4 mL tubes
C1222
Individual adapters for 0.2 mL thermal cycling tubes

5.0 Safety Information

NOTE: Be careful when changing the microcentrifuge tube platform, especially when you have used the unit at
temperatures higher than 60°C. Always wear protective clothing before you handle a hot platform.
The unit will continue to shake for 5 seconds after the lid is opened. Be careful when opening the lid as the parts inside
may still be in motion. In addition, never touch the fan unless the unit is turned off or unplugged.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

Before cleaning the housing unplug the unit. The housing should only be cleaned with a damp cloth and if necessary, a mild soap.

Don't use aggressive or aerosol cleaners.
Do not use the unit near sources of water. Take care to ensure that water will not spill in the device, especially during cleaning

procedures.
Make sure, that all test tubes are closed tightly before placing them into the unit to avoid spilling samples inside the chamber.

In the case of a malfunction, unplug the device and contact your distributor for service.
Do not shake flammable or explosive samples.
2
|
LABNET VORTEMP 1550 SHAKING INCUBATOR