Hardware configurations
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise website (http://
www.hpe.com/servers/ASHRAE).
Emissions Classification (EMC) – Regulatory Information
To view the regulatory information for your product, view the Safety and Compliance Information for System, Storage,
Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise Support Center: http://
www.hpe.com/support/Safety-Compliance-EnterpriseProducts
Environment friendly Products and Approach (End-of-life Management and Recycling)
Hewlett Packard Enterprise offers end-of-life product return, trade-in, and recycling programs, in many geographic
areas, for our products. Products returned to Hewlett Packard Enterprise will be recycled, recovered or disposed of in
a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product
type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett
Packard Enterprise web site. These instructions may be used by recyclers and other WEEE treatment facilities as well
as Hewlett Packard Enterprise OEM customers who integrate and re-sell Hewlett Packard Enterprise equipment.

HPE StoreEasy 1660 Storage mechanical specifications

Maximum (Maximum - 12 LFF hard drives (no rear drives), 2x processors, 2x power supplies, 1x Smart Array, 2x Risers
installed)
Specification
Height
Depth
Width
Weight (approximate)

HPE StoreEasy 1660 Storage input specifications

Specification
Input Requirements (per power supply) - Rated Line
Voltage
BTU Rating - Maximum
Value
8.73 cm (3.44 in)
44.55 cm (17.54 in)
73.02 cm (28.75 in)
54 lbs (24.5 kg)
Value
100 to 120 VAC
200 to 240 VAC
For 800W Power Supply:
3207 BTU/hr (at 100 VAC),
3071 BTU/hr (at 200 VAC),
3112 BTU/hr (at 240 VAC) input for China only
For 500W Power Supply:
1979 BTU/hr (at 100 VAC),
1911 BTU/hr (at 240 VAC),
1965 BTU/hr (at 240 VAC) input for China only