Load (Soiled) End of Washer
3-4
122994-142
5. Install CW1 tee at the end of the cold water supply piping (see
Figure 3-2).
6. Connect other end of tee to condenser cold water supply piping
(see Figure 3-2).
NOTE: If washer is not equipped with condenser, install cold water
supply piping as shown in Figure 3-2, except insert a 1/2" NPT plug
into the right-hand end of CW1 T-connection.
7. Locate manual cold water supply valve and mounting bracket
provided in box labeled "Hardware". Remove valve handle and
insert valve into mounting bracket. Install valve and mounting
bracket over pump motor base, located in washer service
compartment (see Figure 3-3), using two 8-32 x 3/8" screws
provided (CWZ and CW4 installed later, in installation proce-
dure). Reinstall valve handle. Connect cold water supply from T-
connection (CW1) to cold water supply valve (CW3) using
copper piping provided.