Rotary driven 120/230 v ac, 50/60 hz, 1 phase electric pump (22 pages)
Summary of Contents for SKF J Series
Page 1
User and maintenance instructions Air operated grease pump Model , series “J”, for off-highway mining trucks Date of issue October Form number Version ...
Page 2
Contents Declaration of Incorporation* .. U.K. Declaration of Incorporation* . . . Safety* .........
Page 3
N. Hanley Road St. Louis, MO U.S.A. TEL: + () - FAX: + () - Authorized to compile the technical file: SKF Lubrication Systems Germany GmbH Heinrich-Hertz-Straße - Walldorf, Germany TEL: + () - EMAIL: robert.collins@skf.com WEBSITE: www.skf.com...
Page 4
Lincoln Industrial Corporation N. Hanley Road St. Louis, MO U.S.A. TEL: + () - FAX: + () - Authorized to compile the technical file: SKF (U.K.) Limited Canada Close Banbury, Oxfordshire, OX RT, GBR EMAIL: robert.collins@skf.com WEBSITE: www.skf.com This U.K.
Safety* Explanation of signal CAUTION Do not operate equipment without words for safety wearing personal protective gear. The assembly must be installed, maintained Wear eye protection. Protective and repaired exclusively by persons familiar equipment such as dust mask, non-skid with the instructions.
Page 6
To fill reservoir Fig. Model air operated grease pump Use manual filler pump to fill reservoir through filler fitting in pump body. Attach coupler on delivery hose to filler fitting. Stroke pump handle until lubricant weepage is noted at air vent hole in reservoir.
Page 7
Fig. Model air operated grease pump, continued 17 / in (436 mm) 18 / in (461 mm) To lubricate air valve mechanism Refer to Fig. IPB , page . Clean or flush air valve casting to Replace cover gasket, cover and screws.
Injectors To prime system Operation Check each individual injector for proper Supply lines Operation of model pump is fully operation. automatic, controlled by or volt DC After pump reservoir has been filled with electric timer and electric operated solenoid recommended lubricant, remove all plugs in air valve.
Page 9
Fig. IPB Model , continued / in NPTF ) Air exhaust port. ) Tighten to - in.lbf. (3,3 to 4,5 Nm) of torque. ) Tighten to - in.lbf. (10 to 11,2 Nm) of torque. Fig. vent valve / in NPTF / in...
Page 10
Fig. IPB Model / in NPTF ) Tighten to to ft.lbs (13,5 to 20,3 Nm) of torque. ...
Page 11
Service parts list Item Description Part no. Qty. Item Description Part no. Qty. Bead chain Valve seat ) Ring Gasket ) Indicator rod Valve body ...
Troubleshooting Problem Cause Solution Pump operates continuously. Pump has lost prime. Examine lubricant supply. Refill reservoir if necessary. Air pocket trapped in lubricant. Loosen vent plug () one turn. Allow pump to operate until trapped air is pumped out. Close vent plug. Pump continues to operate without discharging Pump check () and steel ball () Remove and clean checks and check seats.
Need help?
Do you have a question about the J Series and is the answer not in the manual?
Questions and answers