Configuring AltiServ

1. Use the default analog trunk port setting to connect to the CallFinder Cellular Gateway.
Interface: Loop Start
Impedance: 600 ohm
Incoming Ring: Single Ring
Caller ID Receiving: FSK
Dial Tone Detection: Enabled
Disconnect Supervisor: Loop break 600ms
Note: If you plan to use CallFinder as a regular trunk line, you may assign a trunk access code to the trunk
port for making an outbound call through a cell phone network. To empower cell phone users with PBX call
control functions, Hold/Transfer/Conference/Get Dial Tone..., you need to set up the following Mobile
Extension configuration.
2. In the Board Configuration Window, click the Board Configuration button. The following screen appears.
3. Click Add/Remove Mobile-trunks button. The following screen appears.
4. Select the trunk port that connects to the CallFinder and add it to the Mobile-Trunk Member List.
5. Stop and restart the switching service, if MobileExt virtual board was not configured in the system.