Important Safety Instructions
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need to refer to
it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
Risk of electric shock. To reduce this risk, observe the
WARNING
!
following precautions.
• ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
• NEVER handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
• MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle. If you have a 2-
prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.
• NEVER bypass grounding wires or remove the ground prong from the plug.
• DO NOT use an extension cord. The electrical outlet should be within the length of the
pump's power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
• DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
• MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to handle
the power requirements noted on the nameplate of the pump.
To reduce the risk of hazards that can cause injury or
CAUTION
!
property damage, observe the following precautions.
• DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
• DO NOT pull on the float switch cord.
• DO NOT operate the pump or control unit if it has been damaged in any way.
• DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.
This pump is for ground water use only.
• DO NOT use in continuous duty applications such as fountain ponds. This pump is rated
for intermittent use only.
• DO NOT disassemble the pump or float switch. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
• When installing or replacing a primary sump pump you should also install a battery
backup sump pump system.
Specifications
1/3 HP Model SI-33V
GPH @ 0'
4000
GPH @ 10'
3200
Pump diameter
9.5"
Volts
115V, 60Hz
Amps
5.0
Items Included:
Pump with vertical float switch
You may also need:
A 1-1/2" PVC pipe adapter to screw into the discharge hole on top of the pump
1-1/2" rigid PVC pipe to connect to the existing plumbing
A check valve or rubber union
PVC pipe cleaner and cement
Wire ties or hose clamps
1/2 HP Model SI-50V
4300
3600
9.5"
115V, 60Hz
6.0

Advertisement

loading

Summary of Contents for Glentronics Basement Watchdog SI-33V

  • Page 1 • DO NOT disassemble the pump or float switch. When service is required, contact Glentronics technical support at 800-991-0466, option 3. Return the product to the manufacturer for any repairs at the following address: Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069 •...
  • Page 2 (e) Lower the pump into the sump by the 1. Visually inspect your pump. Products may be damaged during shipping. If the handle. product has been damaged, contact your place of purchase or Glentronics, Inc. before installation. (f) To avoid debris pouring into the float, it should be positioned on the side of 2.
  • Page 3 Abnormal sound or vibration Blocked intake Clear debris from intake Broken impeller Replace impeller with new one *Consult a licensed electrician. If the above solutions do not solve the problem, contact Glentronics customer service 800-991-0466, option 3.
  • Page 4 • 3 years from the date of purchase, when used intermittently as a sump pump The defective product must be returned directly to the factory, postage prepaid with the original bill of sale or receipt to the address listed below. GLENTRONICS, INC., at its option, will either repair or replace the product and return it postage prepaid.

This manual is also suitable for:

Basement watchdog si-50v