Important Safety Instructions

SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need to refer to
it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
Risk of electric shock. To reduce this risk, observe the
WARNING
!
following precautions.
• ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
• NEVER handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
• MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle. If you have a 2-
prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.
• NEVER bypass grounding wires or remove the ground prong from the plug.
• DO NOT use an extension cord. The electrical outlet should be within the length of the
pump's power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
• DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
• MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to handle
the power requirements noted on the nameplate of the pump.
To reduce the risk of hazards that can cause injury or
CAUTION
!
property damage, observe the following precautions.
• DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
• DO NOT operate the pump if it has been damaged in any way.
• DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.
This pump is for ground water use only.
• DO NOT use in continuous duty applications such as fountain ponds. This pump is rated
for intermittent use only.
• DO NOT disassemble the pump or float switch. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069

Specifications

1/3 HP Model SP-33T
GPH @ 0'
3700
GPH @ 10'
2800
Pump diameter
9.5"
Volts
115V, 60Hz
Amps
4.2

Items Included:

Pump with tether float switch
You may also need:
A 1-1/2" PVC pipe adapter to screw into the discharge hole near the
bottom of the pump
1-1/2" rigid PVC pipe to connect to the existing plumbing
A check valve or rubber union
PVC pipe cleaner and cement
Wire ties or hose clamps
1/2 HP Model SP-50T
3900
3100
9.5"
115V, 60Hz
5.5
Basement Watchdog
Sump Pumps
Instruction Manual &
Safety Warnings
Models SP-33T and SP-50T

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Basement Watchdog SP-33T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Glentronics Basement Watchdog SP-33T

  • Page 1 • DO NOT disassemble the pump or float switch. When service is required, contact Glentronics technical support at 800-991-0466, option 3. Return the product to the manufacturer for any repairs at the following address: Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069...
  • Page 2 NOTICES system is installed without a check • The Basement Watchdog SP-33T and SP-50T come equipped with a built-in air valve or rubber relief valve located near the bottom of the pump, next to the outlet. While the union, saw the pump is active, some water may come out of the valve.
  • Page 3 Replace impeller with new one Broken impeller Discharge PVC pipes not properly secured Secure discharge PVC pipes with appropriate hardware *Consult a licensed electrician. If the above solutions do not solve the problem, contact Glentronics customer service 800-991-0466, option 3.
  • Page 4 • 1 year from the date of purchase, when used intermittently as a sump pump The defective product must be returned directly to the factory, postage prepaid with the original bill of sale or receipt to the address listed below. GLENTRONICS, INC., at its option, will either repair or replace the product and return it postage prepaid.