Download Print this page

Glentronics Basement Watchdog SIT-33D Instruction Manual & Safety Warnings

Sump pumps

Advertisement

Quick Links

Basement Watchdog
Sump Pumps
Instruction Manual &
Safety Warnings
Models SIT-33D
and
SIT-50D
Items Included:
Pump
Dual float and controller
Stainless steel hose clamp
1/3 HP Pump
1/2 HP Pump
SIT-33D
SIT-50D
Important Safety Instructions
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need to refer to it
before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
Risk of electric shock. To reduce this risk, observe the
WARNING
!
following precautions.
• ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
• NEVER handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
• MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain that
it is only connected to a properly grounded, 3-prong receptacle. If you have a 2-prong
receptacle, have a licensed electrician replace it with a 3-prong receptacle according to
local codes and ordinances.
• NEVER bypass grounding wires or remove the ground prong from the plug.
• DO NOT use an extension cord. The electrical outlet should be within the length of the
pump's power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
• DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid
kinking the cord.
• MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to handle the
power requirements noted on the nameplate of the pump.
To reduce the risk of hazards that can cause injury or
CAUTION
!
property damage, observe the following precautions.
• DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
• DO NOT pull on the float switch cord.
• DO NOT expose the control unit to water, rain or snow.
• DO NOT place the controller on the floor. The electrical outlet should be within the
length of the pump's power cord and at least 4 ft above the floor.
• DO NOT operate the pump or control unit if it has been damaged in any way.
• DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.
This product is for ground water use only.
• DO NOT disassemble the pump or control unit. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
• When installing or replacing a primary sump pump you should also install a battery
backup sump pump system.
Specifications
1/3 HP Model SIT-33D
GPH @ 0'
GPH @ 10'
Pump diameter
Volts
115V, 60Hz
Amps
The Dual Float
& Controller
1/2 HP Model SIT-50D
3720
4400
3100
3540
6.2"
6.2"
115V, 60Hz
3.5
4.2
You may also need:
A 1-1/2" PVC pipe adapter to screw
into the discharge hole on top of
the pump
1-1/2" rigid PVC pipe to connect
to the existing plumbing
A check valve or rubber union
PVC pipe cleaner and cement
Wire ties or hose clamps

Advertisement

loading

Summary of Contents for Glentronics Basement Watchdog SIT-33D

  • Page 1 This product is for ground water use only. • DO NOT disassemble the pump or control unit. When service is required, contact Glentronics technical support at 800-991-0466, option 3. Return the product to the manufacturer for any repairs at the following address: Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069...
  • Page 2 NOTICES • The Basement Watchdog SIT-33D and SIT-50D come equipped with a built-in air relief valve located on the top of the pump. While the pump is active, some water may come out of the valve. This is normal. The valve is needed to prevent an air lock within the pump.
  • Page 3 Abnormal sound or vibration Blocked intake screen Clear debris from intake screen Replace impeller with new one Broken impeller *Consult a licensed electrician. If the above solutions do not solve the problem, contact Glentronics customer service 800-991-0466, option 3.
  • Page 4 • 1 year from the date of purchase when used in continuous duty operations such as fountains or ponds The defective product must be returned directly to the factory, postage prepaid with the original bill of sale or receipt to the address listed below. GLENTRONICS, INC., at its option, will either repair or replace the product and return it postage prepaid.

This manual is also suitable for:

Basement watchdog sit-50d