CAUTION WHEN WIRING
•Each cord must be connected depending on its color.
When connecting different cord, attach color tube
around the connector. Connect the coupler to the con-
nector with same color and same pin number.
•Identify the two-colored cord by main color first and
then striped color .
WHITE
TUBE
BLACK TUBE
BLACK CORD
WHITE / RED CORD
•When disconnecting the battery, the minus terminal
must be disconnected first.
•Make sure that the tool such as spanner do not contact
with the frame.
•If the fuse is short-circuited, find out the cause and
repair. Replace with the fuse having the specified
capacity.
WHITE
COUPLER.
WHITE
RED STRIPE
VALIDATION
OF CAPACITY!
SERVICE INFORMATION
•When measuring voltage or resistance of the cord ter-
minal using tester, contact the tester plug behind of the
coupler. Pay attention not to open the cord terminal
and contact the tester plug from the front of the cou-
pler in case of water-proof coupler.
TESTER PLUG
•Recheck the condition of contact, securing and conti-
nuity of each part after maintenance.
•When connecting the battery, the plus terminal must
be connected first.
•After connecting the terminal, apply the grease to the
terminal.
•Connect covers to the terminal after maintenance.
•If there is rust in the terminal, remove the rust with
sand paper prior to connecting.
REMOVE
THE
RUST!