Interfaces; Bus Module At The Systems Interface; Pc-Interface Rs232 At The System Interface - Advanced Energy Thyro-S 1S H 1 Series Manual

Table of Contents

Advertisement

30

5. INTERFACES

The Thyristor Switch of type range Thyro-S...1 are all equipped with
a system interface at terminal strip X22. Either a bus module or a PC
interface with a PC connection can be operated from this.
5.1 BUS MODULE AT THE SYSTEM INTERFACE
The optional bus module enables the Thyro-S range Power Controller
to be connected to a field bus. The bus module is hereby connected
to the Power Controller's system interface (terminal strip X22) with pre-
fabricated cables on the bus module side. Up to eight Thyro-S (or also
combined with Thyro-A) can be connected to the bus system with one
bus module, e.g. Profibus-DP, Modbus RTU, CANopen or DeviceNet.
The bus module connection configuration is identical for all available
bus modules. Further information can be obtained from the operating
instructions of the respective bus module.
REMARK
Further useful functions for the application are possible via field bus by
the access of set point value, actual values, parameters as well as fault
diagnosis.

5.2 PC-INTERFACE RS232 AT THE SYSTEM INTERFACE

The Power Controller is connected to a PC via the serial interface
(COM1, COM2 ...) with the PC-INTERFACE RS232. In addition, an
RS232-DATALINE, Order No. 6000016474 is needed (not crossed, the
connection 2, 3, 4, 5 and 7 are used).
The PC-INTERFACE RS232 must be connected to the terminal strip
X22 according to the instructions included.

Advertisement

Table of Contents
loading

Related Products for Advanced Energy Thyro-S 1S H 1 Series

This manual is also suitable for:

Thyro-s 1s h rl1

Table of Contents