P5 is power monitoring setting, when P5 setting is 0, the power monitoring is the
"real-time voltage" mode. Namely, it is the method to determine the battery capacity
based on real-time battery voltage. When P5 equals to a specified parameter, the power
monitoring is the "smart power" mode (this parameter is determined by the battery
characteristics, ordinary 24V lithium is generally is 4-11, 36V lithium is between 5_15). P5
setting ranges from 0-40, press
P5 parameter setting method is the same to that of P2.
After finishing P5 parameter setting, press
values, and then P5 parameter column stops flashing. Hold
seconds to save & exit P parameter setting environment and return to the display 1. Hold
and
both for about 2 seconds to enter C parameter setting.