Yamato DSR-400 Technical Manual

Yamato DSR-400 Technical Manual

Advertisement

DSR-400
YAMATO CORPORATION
1775 S. Murray Blvd.
Colorado Springs, CO 80916 USA
Tel (719) 591-1500 Fax (719) 591-1045
Technical Manual
YAMATO TECH CORPORATION
#112-19425 Langley By-Pass
Surrey, B.C. V3S 6K1
Tel (604) 533-2338 Fax (604) 533-0827
Canada
YCO-1052-08-04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSR-400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Yamato DSR-400

  • Page 1 DSR-400 Technical Manual YAMATO CORPORATION YAMATO TECH CORPORATION 1775 S. Murray Blvd. #112-19425 Langley By-Pass Colorado Springs, CO 80916 USA Surrey, B.C. V3S 6K1 Canada Tel (719) 591-1500 Fax (719) 591-1045 Tel (604) 533-2338 Fax (604) 533-0827 YCO-1052-08-04...
  • Page 2: Safety Instructions

    DSR-400 Technical Manual Table of Contents Introduction Set-up Procedures A. Setting Auto-Off B. Calibration III. Troubleshooting IV. Wiring Diagram SAFETY INSTRUCTIONS Before using the scale, carefully read, understand and follow the “Safety Instructions” described in this manual. Observe the advice given in every section to ensure proper operation.
  • Page 3: Setup Procedures

    0.5 kg Full Scale The DSR-400 can be powered by 6-AA batteries or by an AC adapter. Use only the AC adaptor sup- plied or an adaptor of the same output characteristics. While operating the DSR-400 on batteries, an automatic-off feature is enabled. It will turn off the scale after two minutes of non-use unless the feature is disabled.
  • Page 4 DSR-400 Technical Manual II Set-up Procedures II.B Calibration 1. Turn the scale on. 2. With all items remove from the scale platform: Press and hold the <ON> key and quickly press the <lb/kg> key three times. The scale will show the raw zero counts. It should be between 2000 and 5000 counts.
  • Page 5: Troubleshooting

    DSR-400 Technical Manual III Troubleshooting Problem Possible Cause Solution The scale will not power on. Batteries dead or incorrectly Test batteries. Reinstall if installed. needed. AC adapter loose or malfunc- Reseat adapter. Replace if tioning. needed. CPU board malfunction. Replace CPU board.