E23: Problems With The Component (Triac) Controlling The Drain Pump - Electrolux Inspiration EWX11831 TC4 Service Manual

Table of Contents

Advertisement

E23

E23: Problems with the component (triac) controlling the drain pump

Checks to perform:
Is the resistance
measurement of the pump
approximately 155÷200 ?
(Measure it between
connectors J15-3 and J15-4
on the board side –(fig.4)-
Y
E
S
Measure it between connectors J15-3 / J15-4
and the appliance body. –(fig.6) -
Is there any dispersion?
Y
E
S
Check/replace the wiring and repeat the
diagnostic cycle to check for any further alarms.
2013 TS/DT-mdm FCPD-dp
Guide to diagnostics of EWX11831 electronic controls
Is the resistance
measurement of the pump
NO
approximately 155÷200?
(Measure it directly on the
pump) –(see fig.5)-
Check/replace the wiring and repeat the diagnostic cycle to check for
!
Check that all the connectors are correctly inserted
NO
Y
E
S
any further alarms.
Replace the main circuit board and repeat
the diagnostic cycle to check for any further
NO
If there are burns on the circuit board,
!
26/71
E23
Replace the pump and repeat
the diagnostic cycle to check
for any further alarms.
alarms.