4.3 Diagnostic test phases

Irrespective of the type of circuit board and the configuration of the selector, after entering the diagnostic
mode, turn the programme selector dial clockwise to perform the diagnostic cycle for the operation of the
various components and to read any alarms.
Concurrently a selector control code is shown on the LDC display for two seconds, before displaying what is
described in the last column of the table below.
(All alarms are enabled in the diagnostic cycle).
Selector
position
TC 3
- The LEDs light up in
sequence, the symbols on the
LCD display light up in in
groups and the backlighting
comes on,
1
- Touch a sensor to turn on the
TC 4
group of icons in the LCD
screen or the corresponding
LED and the buzzer sounds at
the same time.
TC 3
- Door safety interlock
2
- Wash solenoid
TC 4
TC 3
- Door safety interlock
3
TC 4
- Pre-wash solenoid
TC 3
- Door safety interlock
4
- Solenoid valve
TC 4
pre-wash and wash
2013 TS/DT-mdm FCPD-dp
Guide to diagnostics of EWX11831 electronic controls
Components activated
Working conditions
Always active
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
9/71
Function tested
LCD display
User interface
functioning
Water fill to wash
compartment
Water level in
the tub (mm)
Water fill to
pre-wash
compartment
Water level in
the tub (mm)
Water fill to
conditioner
compartment
Water level in
the tub (mm)
599 77 00-82 Rev. 01