E24: Sensing Circuit Of The Component (Triac) Controlling The Drain Pump Faulty - Electrolux Inspiration EWX11831 TC4 Service Manual

Table of Contents

Advertisement

E24: Sensing circuit of the component (triac) controlling the drain
E24
Checks to perform:
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
E31: The analogue pressure switch provides the main circuit board
E31
Checks to perform:
Measure that the circuit is closed
between J3-1, J3-2, J3-3 and the connector
of the analogue pressure switch
(they are three independent wires)
(see fig. 7).
is the wiring between the main circuit board and
the analogue pressure switch ok and is it
connected correctly on both sides?
Replace the analogue pressure switch and
repeat the diagnostic cycle to check for any
further alarm codes.
Is the appliance displaying the same alarm
code again?
Replace the main circuit board and repeat
the diagnostic cycle to check for any further
alarm codes.
If there are burns on the circuit board,
!
see page 69
2013 TS/DT-mdm FCPD-dp
Guide to diagnostics of EWX11831 electronic controls
pump faulty
with a signal outside the limits
Y
E
S
Y
E
S
Analogue pressure
switch
Ω
!
Check that all the connectors are correctly inserted
If there are burns on the circuit board,
!
!
Check that all the connectors are correctly inserted
Reconnect and/or replace the wiring and repeat
the diagnostic cycle to check for any further
NO
Fig. 7
28/71
E24
see page 69
E31
alarms.
DISPLAY
CIRCUIT
BOARD
599 77 00-82 Rev. 01