Four E's Scientific Ironman Operating Instructions Manual

Four E's Scientific Ironman Operating Instructions Manual

Water bath
Table of Contents

Advertisement

Quick Links

Operating Instructions
使用说明书
Water Bath
恒温水浴器
WB101 / Ironman
WB201 / Ironman Ⅱ
V02

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ironman and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Four E's Scientific Ironman

  • Page 1 Operating Instructions 使用说明书 Water Bath 恒温水浴器 WB101 / Ironman WB201 / Ironman Ⅱ...
  • Page 2: Table Of Contents

    Contents Declaration of Conformity 1. Safety Instructions 2. Unpacking 3. Installation 4. Correct use 5. Operation 6. Calibration 7. Faults 8. Maintenance and Cleaning 9. Technical Data 10. Warranty Please read the operating instructions in full before starting up and follow the safety instructions. The appearance and specifications are subject to change without notice.
  • Page 3: Declaration Of Conformity

    DECLARATION OF CONFORMITY Four E’s Scientific water baths meet the requirements of international safety standard IEC61010-1:2001 “Safety requirements for electrical equipment for measurement, control, and laboratory use”...
  • Page 4: Safety Instructions

    1. SAFETY INSTRUCTIONS Read the operating instructions in full before starting up and follow the safety instructions. Socket must be earthed (protective ground contact) before use. • Water must be filled into the chamber before power-on. • Avoid operating the bath without water. •...
  • Page 5 WB101 ① ② ③ ④ ⑤ Transparent lid Stainless-steel chamber LED display ① ② ③ Water bath Base tray ④ ⑤ WB201 ① ② ③ ④ ⑤ ⑥ Transparent lid Cover board Stainless-steel chamber ① ② ③ LED display Water bath Base tray ④...
  • Page 6: Installation

    3. INSTALLATION 3.1 Assembly of the equipment and components The water bath has three main components, the bath, the lid and the base tray. The base tray fits into the bath with the feet downward so that it creates a gap between the bottom of the chamber and the tray.
  • Page 7 alarm. If theprotection program fails to detect the dry-heating, built-in safety temperature cut-out switch will cut off the heating to protect the water bath when heated to a certain temperature . Note: The dry-start protection program is on by default. If you need to turn it off, please refer to 5.8.
  • Page 8: Operation

    5. OPERATION 5.1. Bath controls ⑥ ⑦ ⑧ °C °F ① ② ③ ④ ⑤ ① Preset program ② Over-temperature alarm key ③ Run/Stop ④ Set ⑤ Heating indicator ⑥ ℃ indicator ⑦ ℉ indicator ⑧ Alarm indicator 5.2. Run/Stop When it is displayed OFF, the water bath is in unheated status.
  • Page 9 5.3. Heating temperature setting Method 1: Directly press to enter the temperature setting as following steps: For example: the current temperature is 37.0°C, and set the temperature 50.0°C Operation Display Directly set the heating temperature you 50.0 require Press the set key to save the value then 37.0 exit, it displays the current temperature/OFF Method 2:...
  • Page 10 5.4. Configuring and running temperature presets The bath has 3 presets: . Temperature presets allow P1 P2 P3 you to conveniently store or run bath temperature settings for you routinely use. Before you can use presets, you need to store the values you wish to use in at least one of the presets as the following procedures: For example: configuring the preset P1, the current temperature is 37.0°C, preset...
  • Page 11 Operation Display Select the menu option; Navigate to the switching °C/ °F selection menu option Press the set key to enter °C/ °F switching Switch to °F; C stands for °C, and F stands for°F Press the set key to save the setting, it displays the current temperature/OFF.
  • Page 12 • Set the over-temperature alarm limited temperature to above the water temperature, and the alarm will be turned off. 5.7. Setting the countdown timer The countdown timer range is 1~999 min After the countdown is over, an alarm will sound three times and the heating will stop, “OFF”...
  • Page 13: Calibration

    Press key to save the setting The countdown timer will begin once you save the setting The setting will exit automatically after 5S without operation 5.8. Setting the dry-start protection alarm When the dry-start protection function is on, the bath will stop heating and an alarm will sound when the system detects that the inner chamber is in dry-start status.
  • Page 14 6.2. Dual point calibration Due to the influence of ambient temperature, humidity, and pot structure, the water bath has a certain deviation in temperature measurement. In order to improve the measurement and control accuracy, each single instrument is calibrated before shipment. Includes two calibration options -- low temperature point and high temperature point.
  • Page 15: Faults

    Operation Display Select the menu option Select the high temperature point calibration setting menu option Press set to enter the calibration value Enter the reference thermometer value Press to store the calibration value The setting will exit automatically after 5S without operation Leave the bath to stabilize and check the calibration...
  • Page 16: Technical Data

    9. TECHNICAL DATA Model WB101 WB201 Input 200-240VAC,50/60HZ 200-240VAC,50/60HZ 100-120VAC,50/60HZ 100-120VAC,50/60HZ Power[W] Heating temperature range [℃] Room temp. +5~99 Room temp. +5~99 (under standard atmosphere) Temperature stability [℃] ±0.5 ±0.5 Temperature display accuracy[℃] Time setting range[min] 1-999 1-999 Dimensions(W x H x D)[mm] 252*188*285 394*188*285 Reservoir capacity[L]...
  • Page 17 目 录 前言 符合性声明 1. 安全说明 2. 开箱指引 3. 安装 3.1. 仪器安装 3.2. 仪器摆放 3.3. 电源供应 4. 操作说明 4.1. 操作规范 4.2. 操作设置 4.3. 校准 5. 故障排除 6. 清洁与维护 7. 技术参数 8. 保修 请仔细阅读说明书并在说明书的操作指导下安全使用本仪器。 外形和性能指标如有变动,概不另行通知。...
  • Page 18: 符合性声明

    前言 欢迎使用《恒温水浴器使用说明书》。用户在使用本仪器前应仔细阅读本 说明书,了解相关注意事项,并按照说明书中的指导和规范进行操作。 符合性声明 本产品符合IEC61010-1:2001 “测量、控制和实验室用电气设备的安 全要求”的相关规定。...
  • Page 19: 安全说明

    1. 安全说明 • 为保证安全,使用本仪器前请确认电源插座接地良好。 • 使用时必须先加水到内锅里,再接通电源。 • 避免干烧。 • 以下标志在设备和使用说明书中表示: 注意:表面在使用期间和使用后可能会很热。 注意:必需接地。 2. 开箱指引 • 请小心拆除包装并检查仪器 • 如果发现任何破损,请填写破损报告并立即通知货运公或联系供货商。 注意: • 如果设备/适配器有明显损坏,请不要连接电源线。 • 包装清单 型号 Ironman Ironman Ⅱ 主机 1台 1台 盖板 1个 透明盖子 1个 2个 托盘 1个 1个 电源线 1条 1条...
  • Page 20 Ironman ① ② ③ ④ ⑤ ① 透明盖子 ② 不锈钢内锅 ③ 控制面板 ④ 水浴器主体 ⑤托盘 Ironman Ⅱ ① ② ③ ④ ⑤ ⑥ ① 透明盖子 ② 盖板 ③ 不锈钢内锅 ④控制面板 ⑤ 水浴器主体 ⑥ 托盘...
  • Page 21: 仪器安装

    3. 安装 3.1. 仪器安装 水浴器有三个主要组成部分:水浴器主体、透明盖子和托盘。托盘支撑 脚需朝下放置,确保内锅与托盘之间存在间隙。 注意: • 为达到最佳的温度稳定性,在使用水浴器时应该避免托盘与内锅的侧 面直接接触。 • 在使用过程中,透明盖子可能会变热,仅可通过手把提起盖子。 • 盖子有一个通风孔/温度计孔,不要密封该孔,避免内部积聚压力。 3.2. 仪器摆放 将水浴器置于水平且周围无易燃物品的桌面上,确保电源插头和开关容易 触及。 3.3. 电源供应 - 检查电源插头标签上的电源电压和插头类型是否与您的电源插座相符, 电源插座必须接地。 - 若要断开设备与电源的连接,请从电源插座上拨出电源插头。 4. 操作说明 4.1. 操作规范 4.1.1避免干烧 避免在内锅没有水的情况下使用水浴器,干烧会影响水浴器关键部件的 使用寿命。 水浴器内置的干烧保护程序,在大多数的情况下都能够检测到干烧现象, 并阻止水浴器继续加热。在这种情况下,显示板会显示” ”并响起 警报声。如果干烧保护程序未能够检测到干烧现象,内置的温控保护开 关会在加热到一定温度时断开加热,保护水浴器。 注意: 干烧保护程序默认为开启,如需切换为关闭,操作步骤见 4.2.8 干烧保护 设置”。...
  • Page 22: 操作设置

    - 采取适当的预防措施,防止水意外溢出。 4.1.3 使用透明盖子 - 当温度设置在60℃以上时,盖上透明盖子可以保证正常的温度控制, 同时保证水温达到设定值。 - 使用透明盖子可以避免过量的水份蒸发。 4.1.4 使用托盘 - 使用托盘可以改善容器内的温度控制。 - 不要将平口容器或其它物品直接放入不锈钢内锅,避免与内壁直接接 触。 4.2. 操作设置 ⑥ ⑦ ⑧ 4.2.1 控制面板 °C °F ① ② ③ ④ ⑤ ① 预设程序按键 ② 过温保护按键 ③ 启动/关闭加热按键 ④ 设置按键 ⑤ 加热指示灯 ⑥...
  • Page 23 4.2.3 加热温度设置 方法一:直接按 进入温度设置,设置步骤如下: 示例:温度设置为50.0℃,当前温度为37.0℃; 操 作 面板显示 50.0 快速加热温度设置 37.0 保存设置并退出,显示当前温度/OFF 方法二:按 进入温度设置子菜单进行温度设置,设置步骤如下: 示例:温度设置为55.0℃,当前温度为37.0℃; 操 作 进入一级菜单 进入温度设置子菜单 设置温度值 保存设置并退出,显示当前温度/OFF 方法三:调用预设程序 ,操作步骤见4.2.4“预设程序设置和 P1 P2 P3 调用”。 4.2.4 预设程序设置和调用 水浴器有3个预设温度按键 ,可用于设置或调用常用的温度设 P1 P2 P3 置。预设程序在调用前需先设置加热温度。 设置预设程序步骤如下: 示例:预设P1程序,预设温度为50.0℃,当前温度为37.0℃; 操作 选择需要设置的预设程序按键 设置预设加热温度 再次按下预设程序按键,保存设...
  • Page 24 操 作 按需要调用的预设程序按键 确认选择预设程序,显示当前温度/OFF 操 作 进入一级菜单 选择°C/°F切换设置子菜单 进入°C/°F切换设置子菜单 切换°F;C代表°C,F代表°F 保存设置,显示当前温度/OFF 操 作 进入过温设置菜单 设置过温保护温度 保存设置并退出,显示当前温度/OFF...
  • Page 25 如果液体温度超过过温保护温度,水浴器将停止加热,显示 并发出 警报声。可通过以下操作关闭警报: - 关闭电源,警报关闭,待水温降至过温保护温度以下,重启机器,; - 加入冷水,待水温降至过温保护温度以下,警报关闭; - 将过温保护温度设置至水温以上,警报关闭。 4.2.7. 倒计时设置 倒计时的设定范围为1~999分钟。 倒计时结束后会发出3声报警声并停止加热,面板显示OFF。 注意: 1. 当倒计时时间≥10分钟时,倒计时时间隐藏,面板显示实时温度; 2. 当倒计时时间<10分钟时,面板实时显示倒计时时间; 3. 只有在加热状态才会进行倒计时,停止加热即停止倒计时; 4. 当水浴器处于加热状态时,保存倒计时设置后,倒计时立即开始; 5. 当水浴器处于非加热状态时,保存倒计时设置后,需按下“启动/关闭 加热按键”开始倒计时; 6. 倒计时设置与温度设置无关。在设置倒计时,需考虑加热到设置温度 所需的时间。 倒计时设置步骤如下: 示例:倒计时时间由0设置为10分钟; 操 作 进入一级菜单 选择倒计时设置子菜单 进入倒计时设置子菜单 当倒计时为0时,显示OFF 当倒计时非0时,显示倒计时时长 设置倒计时时间 右下角“•”代表正处于倒计时设置中 按 保存设置,否则设置无效...
  • Page 26 4.2.8 干烧保护设置 通过干烧保护设置,可以开启/关闭干烧保护功能。 当干烧保护开启时,系统检测到内锅处于干烧状态会停止加热并发出报 警声。当干烧保护关闭时,系统不发出报警声,并且会继续加热到所设 置的温度。 示例:干烧保护由“ON”设置为“OFF”,当前温度为37.0℃; 操 作 4.3. 校准 4.3.1 校准条件 为保证精确的校准结果,需要良好的校准条件: - 温度计精度为水浴器显示精度10倍以上; - 在没有空气对流,稳定的环境温度(+/-1ºC)下进行校准; - 待液体达到校准设定温度,并稳定30分钟以后再进行校准。...
  • Page 27 4.3.2 双点校准 水浴锅因受环境温度、湿度、锅体结构的影响,测温存在一定偏差,为 提高测量及控制精度,出厂前已进行温度校准。 校准点包含低温点和高温点。低温点LCP选择30 ~ 40℃,高温点HCP选 择55℃以上。 低温点校准步骤如下: 示例:校准前面板显示32.0℃,内锅液体实际温度37.0℃; 校准后面板显示36.8℃,内锅液体实际温度37.0℃; 操 作 进入一级菜单 选择低温点校准子菜单 进入低温点校准子子菜单 根据内锅液体实际温度校准温度值 按 保存设置,否则设置无效 无操作5s后自动退出设置 等待内锅液体温度稳定, 检测校准是否合格 高温点校准步骤如下: 示例:校准前面板显示60℃,内锅液体实际温度65.0℃; 校准后面板显示64.7℃,内锅液体实际温度65.0℃; 操 作 进入一级菜单 选择高温点校准子菜单 进入高温点校准子菜单 根据内锅液体实际温度校准温度值 按 保存设置,否则设置无效 无操作5s后自动退出设置 等待内锅液体温度稳定, 检测校准是否合格...
  • Page 28: 故障排除

    过温报警 1.降低锅内水温。 1.锅内起始水温高于OTP值。 2.重新设置OTP值。 2.OTP设置是否过低。 干烧报警,锅内无水或水量 关机,并添加水。 少于最小水量。 6. 清洁与维护 正确地使用和维护仪器,使其处于良好的工作状态,有利于延长使用寿命。 清洁和维护之前必须切断电源。 除清洁外,无需常规维护。用醮有肥皂液、洗洁精或酒精的湿布清洁设备 的外部,晾干后再继续使用。注意不要使用带腐蚀性的化学试剂进行清洁。 内部元件无需维护更换。 7. 技术参数 型号 Ironman Ironman Ⅱ 输入 200-240VAC,50/60HZ 200-240VAC,50/60HZ 100-120VAC,50/60HZ 100-120VAC,50/60HZ 功率/ W 温度范围/℃ (在标准大气压下) 室温+5~99 室温+5~99 稳定性/℃ ±0.5 ±0.5 温度显示精度/℃ 倒计时时长/min 1-999 1-999 外形尺寸/mm...
  • Page 29 8. 保修 根据本公司保修规定本机保修 2 年。保修期内如果有任何问题请联络您 的供货商,您也可以将仪器附发票和故障说明直接发至我们公司,经我 方事先确认后运费由贵方承担。保修不包括零件的自然磨损,也不适用 于由于过失、不当操作或者未按操作说明书使用和维护引起的损坏。...