Page 1
AeroTrak ® Handheld Airborne Particle Counter Model 9303 Operation Manual P/N 6002277, Revision K October 2022 www.tsi.com...
Page 2
Start Seeing the Benefits of Registering Today! ® ® Thank you for your TSI instrument purchase. Occasionally, TSI releases information on software updates, product enhancements ® and new products. By registering your instrument, TSI will be able to send this important information to you. http://register.tsi.com As part of the registration process, you will be asked for your comments on TSI products and services.
Page 3
® AeroTrak Handheld Airborne Particle Counter Model 9303 Operation Manual SHIP TO/MAIL TO: E-mail address: TSI Incorporated answers@tsi.com 500 Cardigan Road Shoreview, MN 55126-3996 Website: http://www.tsi.com U.S. INTERNATIONAL Technical Support: Technical Support: (800) 680-1220/(651) 490-2860 (001 651) 490-2860 Fax: Fax: (651) 490-3824 (001 651) 490-3824...
M a n u a l H i s t o r y ® The following is a manual history of the AeroTrak Handheld Airborne Particle Counter, Model 9303 Operation Manual (P/N 6002277). Revision Date November 2008 January 2009 June 2009 July 2010 September 2010 February 2011...
Page 6
Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller. Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems.
C o n t e n t s Manual History .................... ii Warranty ..................... iii Contents ...................... v Safety Information ..................vii Laser Safety ..................vii Labels ....................viii Description of Caution/Warning Symbols ..........ix Caution ....................ix Warning ....................ix Caution or Warning Symbols .............
Page 8
CHAPTER 7 Contacting Customer Service ........... 7-1 Technical Contacts ................7-1 International Contacts ..............7-1 ® Returning the AeroTrak Handheld Airborne Particle Counter for Service ..................7-3 APPENDIX A Specifications ..............A-1 Compliance ..................A-2 Dimensional Diagram ................. A-3 ® AeroTrak Handheld Airborne Particle Counters...
S a f e t y I n f o r m a t i o n This section gives instructions to promote safe and proper handling of the ® AeroTrak Handheld Airborne Particle Counters. I M P O R T A N T N O T I C E There are no user-serviceable parts inside the instrument.
L a b e l s Advisory labels and identification labels are attached to the outside of the particle counter housing and to the optics housing on the inside of the instrument. 1. Serial number label (back panel) 2. Laser radiation label DANGER! (internal) INVISIBLE LASER RADIATION...
D e s c r i p t i o n o f C a u t i o n / W a r n i n g S y m b o l s Appropriate caution/warning statements are used throughout the manual and on the instrument that require you to take cautionary measures when working with the instrument.
G e t t i n g H e l p To obtain assistance with this product or to submit suggestions, please contact Customer Service: ® Incorporated 500 Cardigan Road Shoreview, MN 55126 U.S.A. Fax: (651) 490-3824 (USA) Fax: 001 651 490 3824 (International) Telephone: 1-800-680-1220 (USA) or (651) 490-2860 International: 001 651 490-2860 E-mail Address:...
Page 13
C H A P T E R 1 I n t r o d u c t i o n a n d U n p a c k i n g ® The AeroTrak Model 9303 Handheld Airborne Particle Counter (particle counter) is a lightweight, handheld particle counter with a backlit LCD display.
Page 14
Qty. Item Description Part/Model Reference Picture AC power adapter 700021 and country- specific plugs Isokinetic inlet 700003 Battery Pack 700019 Computer cable, 700036 USB A to mini-B HEPA zero filter 700005 ® TrakPro™ Lite Available on TSI website: Secure Software https://tsi.com/support/tsi- for 21 CFR Part software-and-firmware/...
Optional Accessories The following photo and table list optional accessories. If you ordered optional accessories, make certain they have been received and are in working order. Item Description Part/Model Ref. Stainless Steel Isokinetic 700004 inlet Isokinetic probe (used 700001 AL with tubing) 700002 SS 0.1 cfm Barb Inlet Fitting...
C H A P T E R 2 G e t t i n g S t a r t e d This chapter provides information to help you use the Model 9303 including: • Installing the Isokinetic Inlet • Providing Power •...
P r o v i d i n g P o w e r The Model 9303 may be powered using its internal rechargeable lithium- ion battery or through an AC power cord. NOTICES • When using AC power, the battery is charging when the red LED next to the power connector is on.
To Use AC Power 1. Remove the AC transformer parts from their package and identify the appropriate plug for your needs. Plugs are available for all common countries. 2. Remove the insert from transformer using the slide lock and tilt the insert out.
5. Plug the DC end of the transformer cord into the counter. 6. Plug the AC end of the transformer cord into an AC outlet. 7. The Power LED lights when the battery is charging. When the Power LED is off, the battery is fully charged. 8.
Page 21
C H A P T E R 3 O p e r a t i o n The Model 9303 is controlled using the integral keys and the backlit display. Isokinetic Inlet Backlit Display Key Pad Power USB Port Adapter Socket To turn on the instrument, press the On/Off key.
Page 22
Particle Counter MODEL: 9303-01 SERIAL: 93030837003 REV: 2.10 Splash Screen The instrument is ready for operation when the default screen (shown below) appears. 0.3µm 1.0µm 5.0µm Loc # 001 0002/1500 Stopped STime 01:00 HTime 00:05 MENU Default Screen NOTICE To turn off the instrument, press and hold the On/Off key for 5 seconds. The instrument turns off.
W a r m - u p T i m e An initial warm-up period of 15 minutes is recommended before sampling with the Model 9303. The warm-up period allows time for the optics to reach a steady-state temperature. This will result in more repeatable results.
Basic Operation This section explains the basic operation for using the keypad and starting sampling. Using the Keypad Left Soft Right Soft Return Previous On/Off Screen Enter Down Use the up and down keys to highlight a menu or a menu option then: •...
Page 25
Start Sampling To start sampling, press the left soft key (below “RUN”). The Model 9303 begins collecting samples immediately if set to manual mode or according to the parameters you have set for automatic mode. 0.3µm 19031 1.0µm 8186 5.0µm 4671 Loc# 001 0026/1500...
S e t t i n g s M e n u The Settings Menu lets you set language (supported in future), current time and date, select the time and day format, and set certain screen settings. SETTINGS MENU Language English Set Time 2:41:55 PM...
S a m p l e M e n u The Sample Menu sets sample mode, cycle mode, sample time, hold time, cycle count, sample units, and channel 2 size. SAMPLE MENU Sample Mode COUNTS Cycle Mode AUTO Sample Time 01:00 Hold Time 00:30...
Option Description Parameters Use < and > to set Sample Units Liter; cubic feet the sampling units. Channel 2 Size Use < and > to set 0.5, 1.0, 2.0, 2.5 µm the bin size for channel 2. (This is the only channel that can be set to more than one value.) NOTICE...
BUFFER RECORD Record#: 0313 Date: 12/27/08 Time: 05:50:45 0.3µm 000566473 0.5µm 000534571 5.0µm 000072056 Location: Sample Time: 01:00 Hold Time: 00:00 < > Example of a Buffer Record Use the < and > softkeys to scroll through the records, Enter to go back one screen and ESC to go back to the Buffer Menu.
Page 30
The following table describes the options of this menu and the parameters you can set. C A U T I O N If you turn Data Logging off, no data will be saved to the buffer. Option Description Parameters Pump Speed Press the Enter key to go to a 0 to 255 secondary screen where you can...
C H A P T E R 4 D a t a H a n d l i n g U S B C o m p u t e r C o m m u n i c a t i o n Mini USB Port The Model 9303 is equipped with a USB-compatible cable for uploading and downloading information to a PC.
C H A P T E R 5 M a i n t e n a n c e NOTICE There are no user-serviceable parts inside this instrument. Opening the ® instrument case may void the warranty. TSI recommends that you ®...
Page 35
C H A P T E R 6 T r o u b l e s h o o t i n g Symptom Possible Cause Corrective Action Counts are too low. Instrument is being Operate instrument within operated outside specifications.
Page 36
Symptom Possible Cause Corrective Action Instrument does not HEPA filter is not Check that the HEPA meet zero count connected properly filter has been tightly specification and room air is leaking connected to the inlet. (<1 particle/5 min). into the HEPA filter Check that rubber O-ring (black) on the inlet is assembly.
® or contact TSI Customer Service at 1-800-680-1220 (USA) or (651) 490-2860. International Contacts Service TSI Instruments Singapore Pte Ltd 150 Kampong Ampat #05-05 KA Centre Singapore 368324 Telephone: +65 6595-6388 Fax:...
Page 38
Cressex Business Park High Wycombe, Buckinghamshire HP12 3ST UNITED KINGDOM Telephone: +44 (0) 149 4 459200 E-mail: tsiuk@tsi.com Technical Support TSI Instruments Singapore Pte Ltd 150 Kampong Ampat #05-05 KA Centre Singapore 368324 Telephone: +65 6595-6388 Fax: +65 6595-6399 E-mail: tsi-singapore@tsi.com...
® R e t u r n i n g t h e A e r o T r a k H a n d h e l d A i r b o r n e P a r t i c l e C o u n t e r f o r S e r v i c e and complete the on-line “Service Visit our website at tsi.com/service...
Page 41
A P P E N D I X A S p e c i f i c a t i o n s All specifications meet or exceed JIS B9921. They are subject to change without notice. Size Range ....0.3 to 25 µm Channel Sizes ....
Standards ..... CE, JIS B9921, ISO 21501-4 Warranty ....... 1 year (extended warranties available) Operating Conditions . 41° to 95°F (5° to 35°C) temperature and 20% to 95% non-condensing relative humidity Storage Conditions ..32° to 122°F (0° to 50°C) temperature and up to 98% non-condensing relative humidity Included Accessories ..