Page 8
Thank you for purchasing a product from the V-TUF Industrial Cleaning Equipment range. V-TUF is focused on research and development to make sure you are fully satisfied with your purchase. Please read this manual carefully and follow the instructions to ensure you get the best performance from this machine.
3. Make sure that the electrical data of the appliance, shown on the label, corresponds to those of the mains supply. 4. The appliance must only be used with V-TUF accessories and spare parts as these ensure safe and perfect operation.
IMPORTANT INFORMATION Never use the machine if you are unsure, or become uncertain due to any faults of any kind, including those not mentioned in this manual. Technical Information Model XR11000 Capacity 110 Litres 110 & 240 Volts Working Voltage...
Safety Instructions These instructions are for the user’s safety, and all users of the V-TÜF cleaning equipment should ensure to have read this literature before using the machine. Do not use with a damaged cable. Do not run over the cable. ...
Page 12
4. Do not touch the plug and/or socket with wet hands. ELECTRIC SHOCK RISK. 5. Do not soak the appliance or spray it with liquid substances. SHORT-CIRCUIT. 6. In the case of extractor models, only use detergents compatible with vacuum and pipe covering materials.
Page 13
Maintenance, cleaning and repair Only perform the maintenance work described in this booklet on the equipment. In case of uncertainty, contact the dealer or an authorized service centre. BEFORE FIRST USE Vacuum assembly and testing Before using the device, check that: No foreign elements are present within the container.
Page 14
MAINTENANCE: FILTER REMOVAL ATTENTION Be careful to not stir up dusts when performing cleaning operations, filter checks or filter replacements. Use a protective mask. Or a V-TUF filter cleaning box. Replacing the filter bag Undo the head clips and remove the head.
Page 15
Remove the used filter bag and close the inlet with the tag as shown below. Dispose of the bag in the correct manner. Fit the new filter bag, making sure that the bag’s membrane seal fits perfectly over the internal slot of the tank inlet and that the bag fits neatly around the edge of the tank internal.
TROUBLESHOOTING PROBLEM PROBABLE CAUSE PROBABLE SOLUTION The machine does not No current. Check main fuse, power cord, start plug and outlet. The machine suddenly Because of overheating, After the machine has cooled stops the thermal protection turns down, you can turn the power the Machine off (feature only on again and begin to use the available on extraction...