Page 1
MIDI H 110 INDUSTRIAL VACUUM CLEANER Please read this manual before using the MIDI H 110 All Errors & Omissions Excused – Speci cation May Change Without Notice – Please Refer To www.v-tuf.co.uk For the Latest Version...
Page 2
VTVS7023(5M) HOSE - 5M 32mm Yellow Vacuum Hose With End To Fit WND/1 - for NEW MIGHTY, NEW MIDI FLOOR HEAD - 420MM WIDE Wet & Dry WITH WHEELS V-TUF 32 MM BIO324WD WND/1 V-TUF PROFESSIONAL TUBE SET - 32MM STAINLESS STEEL 3 PIECE...
3. Make sure that the electrical data of the appliance, shown on the label, corresponds to those of the mains supply. 4. The appliance must only be used with V-TUF accessories and spare parts as these ensure safe and perfect operation.
Page 8
Ø32mm Accessories Kit Power Cable Safety Instructions These instructions are for the user’s safety, and all users of the V-TUF cleaning equipment should ensure to have read this literature before using the machine. Do not use with a damaged cable.
SAFETY PRECAUTIONS Caution: what to do 1. All power conduction parts must be protected against water. SHORT-CIRCUIT RISK. 2. All services or maintenance performed on the appliance must always be done with the plug disconnected from the power supply. 3. Operation with a residual current circuit breaker provides extra protection for the operator (I_n=30 mA).
VACUUM CLEANER – CLASS H SAFETY INDICATIONS Operator safety This manual is to be considered as an integral part of the general user manual and provides the necessary instructions for the special class H dust vacuum cleaners. Therefore the supplied general instruction booklet must be read beforehand. In addition to the user instructions and the current regulations in the country of use, the sector’s recognised technical regulations for the safe and appropriate use of this equipment must also be followed.
Maintenance, cleaning and repair Only perform the maintenance work described in this booklet on the equipment. In case of uncertainty, contact the dealer or an authorized service centre. Before performing any cleaning or maintenance operations upon the device, remove both the electrical and compressed air power supply cables.
Page 12
MAINTENANCE: FILTER REMOVAL ATTENTION Be careful to not stir up dusts when performing cleaning operations, filter checks or filter replacements. Use a protective mask. Or a V-TUF filter cleaning box. Replacing the filter bag Undo the head clips and remove the head.
Page 13
Remove the used filter bag and close the inlet with the tag as shown below. Dispose of the bag in the correct manner. Fit the new filter bag, making sure that the bag’s membrane seal fits perfectly over the internal slot of the tank inlet and that the bag fits neatly around the edge of the tank internal.
TROUBLESHOOTING PROBLEM PROBABLE CAUSE PROBABLE SOLUTION The machine does not No current. Check main fuse, power cord, start plug and outlet. The machine suddenly Because of overheating, After the machine has cooled stops the thermal protection turns down, you can turn the power the Machine off (feature only on again and begin to use the available on extraction...