<INITIAL SET UP/INFORMATION> (continued)

INFORMATION/SERVICE

In the <INFORMATION/SERVICE> screen, the log list/de-
vice list during power failures, etc., can be checked and
the menus can be reset. At the bottom of the menu screen,
the accumulated operation time since the beginning of us-
age is displayed.

HDD/CFC INFORMATION

The recorded range of the HDD or Compact Flash Card
inserted in the unit can be checked.
1. (To check the recorded range of the HDD • • • )
Press the SET UP button
UP/INFORMATION>
<INFORMATION/SERVICE> screen. Display the desired
setting and confirm.
• The <INFORMATION> screen appears.
<INFORMATION>
HDD
MASTER
SLAVE
START
END
2. (To check the recorded range of the Compact Flash Card
inserted in the unit or to check the menu information recording
status • • • )
Select the SET UP button
UP/INFORMATION>
<INFORMATION/SERVICE> screen and turn the SHUTTLE
ring clockwise.
• The <INFORMATION> screen of the Compact Flash Card
inserted in the unit is displayed.
<INFORMATION>
CFC
CAPACITY
MENU INFORMATION
START
END
3. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.

WARNING LOG LIST

The WARNING LOG LIST enables to check the number of
failure, date, time and type of failure during power failures,
etc.
<INFORMATION/SERVICE>
HDD INFORMATION
CFC INFORMATION
>>WARNING LOG LIST

RESET TO FACTORY SETTING

HDD DATA CLEAR
CFC DATA CLEAR
ELAPSED TIME
1. Press the SET UP button
UP/INFORMATION>
<INFORMATION/SERVICE> screen. Turn the SHUTTLE ring
clockwise.
• The <WARNING LOG LIST> screen appears.
• The WARNING LOG LIST can display up to 1000 items. When
the number of items exceed this limit, the latest 1000 items
are displayed.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
48
<SETTINGS>
<INITIAL SET
}
}
Select "HDD INFORMATION" in the
}
HDD(120GB)
NONE
02-02-2003
00:00:00
04-04-2003
12:30:15
<SETTINGS>
<INITIAL SET
}
}
Select "CFC INFORMATION" in the
}
64MB
02-02-2003
00:00:00
02-02-2003
00:00:10
10H
<SETTINGS>
<INITIAL SET
}
}
Select "WARNING LOG LIST" in the
}
button/turn JOG dial counterclockwise : Selection moves
to the next number.
button/turn JOG dial clockwise : Selection moves to the
previous number.
button : Displays the page with date prior to the date of
the currently opened page.
button : Displays the page with date newer than the date
of the currently opened page.
• To reset the WARNING LOG LIST, press the WARNING
RESET button for 5 seconds.
When a failure occurs while the <WARNING LOG
LIST> is being displayed, exit the screen and dis-
play the screen again. A new item will be added to
the list.
Failures displayed in the WARNING LOG LIST (
see page 72).
<WARNING LOG LIST>
NO.
DATE
>>0001 02-02-03 10:00:00 ALM ON
"P-LOSS" : Power failure.
"SYS RST" : Reset button was pressed and the unit
was reset.
"ALM OFF" : ALARM INTERRUPT button was
pressed and the unit was put on interruption.
"ALM ON" : ALARM INTERRUPT button was
pressed and the alarm interrupt was cancelled.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
RESET TO FACTORY SETTING
Menu screen settings are reset.
1. Press the SET UP button
}
UP/INFORMATION>
Select "RESET TO FACTORY
}
SETTING" in the <INFORMATION/SERVICE> screen. Turn
the SHUTTLE ring clockwise.
• The <RESET TO FACTORY SETTING> screen appears.
• When not resetting menu screen settings, turn the SHUTTLE
ring counterclockwise.
<RESET TO FACTORY SETTING>
>>EXECUTE
SHUTTLE>>:EXECUTE,<<:CANCEL
2. Turn the SHUTTLE ring clockwise.
• The menu screen settings are reset.
3. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
TIME
WARNING
<SETTINGS>
<INITIAL SET
}

Advertisement

Table of Contents
loading

Table of Contents