TROUBLESHOOTING

Condition/Problem
No display/partial display/
unit will not turn on
Unit operates but Contact
HR not displayed
Unit operates but
Bluetooth
HR not
®
displayed
Unit operates but
Bluetooth
HR displayed
®
incorrectly
No speed/RPM reading,
Console displays "Please
Pedal" error code
32
Things to Check
Check electrical (wall)
outlet
Check connection at front
of unit
Check data cable integrity
Check data cable
connections/orientation
Check console display for
damage
Console Display
HR cable connection at
Console and base of mast
HR cable box connection
Sensor grip
Dry or calloused hands
Static Handlebar
HR monitor (not provided)
HR monitor batteries
Interference
Replace HR monitor
Replace Console
Connected to previous
user
Check data cable integrity
Check data cable
connections/orientation
Check magnet position
(requires shroud removal)
Check Speed Sensor
(requires shroud removal)
Make sure unit is plugged into a functioning wall outlet.
Connection should be secure and undamaged. Replace
adapter or connection at unit if either are damaged.
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Be sure cables at base of mast and at back of console are con-
nected securely and oriented properly. Small latch on connec-
tor should line up and snap into place.
Check for visual sign that console display is cracked or other-
wise damaged. Replace Console if damaged.
If Console only has partial display and all connections are fine,
replace the Console.
If the above steps do not resolve the problem, contact Cus-
tomer Service (if inside US/Canada) or your local distributor (if
outside US/Canada).
Be sure cable is connected securely to Console.
Be sure cables from handlebars and cable to Console are
secure and undamaged.
Be sure hands are centered on HR sensors. Hands must be
kept still with relatively equal pressure applied to each side.
Sensors may have difficulty with dried out or calloused hands.
A conductive electrode cream (heart rate cream) can help
make better conduct. These are available on the web or at
medical or some larger fitness stores.
If tests reveal no other issues, Static Handlebar should be
replaced.
Follow the troubleshooting instructions provided with the
device.
If monitor has replaceable batteries, install new batteries.
Try moving unit away from sources of interference (TV, Micro-
wave, etc).
If interference is eliminated and HR does not function, replace
HR monitor.
If HR still does not function, replace Console.
The Console may be still connected to the previous user. Push
Connect Bluetooth
button to disconnect from them and push
®
again to connect to your device.
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Be sure each cable is connected securely and oriented proper-
ly. Small latch on connector should line up and snap into place.
Magnet should be in place on pulley.
Speed sensor should be aligned with magnet and connected to
data cable. Realign sensor if necessary. Replace if there is any
damage to the sensor or the connecting wire.
Solution