Terminals (IS version)

1 - +V DC
The positive power supply from the integrator connection.
2 – Speed Out
The positive output connection of the measurement loop.
GND – Ground
A ground connection. Do not use this ground for the cable shield.
Note
• Ground the cable shield at the integrator end only!
• For optimal performance the housing of the Speed Sensor must be connected to a reliable
earthed ground.
4.3.1

Terminal connections to Siemens Milltronics integrators

WS300 IS
1
2
4.3.2

Terminal connections to SIWAREX FTC integrator

WS300 IS
1
2
Connect CI- to Common.
SITRANS WS300
Operating Instructions, 04/2021, A5E45050935-AC
IS Switch Isolator Terminal
1
3
7
8
IS Switch Isolator Terminal
1
3
7
8
Connecting
4.3 Terminals (IS version)
Integrator
speed signal input
- excitation
FTC
CI+
- excitation