1. Open stove door. Remove any items neces-
sary for easy access to the pilot (for example:
logs, screens, etc.).
2. Follow appropriate lighting instructions found
previously. Instead of pushing and releasing the
piezo button, light a match and hold the flame
to the end of the pilot and ignite the pilot.
Turn off heater and allow to cool before
cleaning. Disconnect electrical power before
cleaning or servicing.

CLEANING AND SERVICING

Annual inspection and cleaning by your dealer or quali-
fied service technician is recommended to prevent
malfunction and/or sooting.
Remove logs, handling carefully by holding gently at each
end. Gloves are recommended to prevent skin irritation
from ceramic fibers. If skin becomes irritated, wash gently
with soap and water. Refer to manual for correct log place-
ment.
PERIODIC CLEANING - See parts diagram for loca-
tion of items discussed below.
Do not use cleaning fluid to clean logs or any part of
heater.
Brush logs with soft bristle brush or vacuum with
brush attachment.
Vacuum loose particles and dust from the front and
rear burners, control and piezo covers and grate
weldment.
Inspect and clean burner air intake holes. Remove
lint or particles with vacuum, brush, or pipe cleaners.
Failure to keep air intake holes clean will result in
sooting and poor combustion.
External case should be dusted and wiped with a
moist cloth.
20
OPERATING INSTRUCTIONS / CLEANING and SERVICING

MATCH LIGHTING INSTRUCTIONS

3. After control knob has been released and pilot
stays lit, reinstall any items that were removed
for pilot access.
4. Call a qualified service technician for repair or
replacement of the piezo ignitor.
ANNUAL CLEANING/INSPECTION - Refer to parts
diagram for location of items discussed below.
Inspect and clean burner air intake holes. Remove
lint or particles with vacuum, brush or pipe cleaners.
Failure to keep air intake holes clean will result in
sooting and poor combustion.
Inspect and clean all burner ports.
Inspect ODS pilot for operation and accumulation of
lint at air intake holes.
Verify flame pattern and log placement for proper
operation.
Verify smooth and responsive ignition of main burner
and rear burner.