Unvented Cast Iron Gas Stoves
The positioning of the logs is critical to
the safe and clean operation of this heater.
Sooting and other problems may result if the
logs are not properly and firmly positioned
in the appliance. Never add additional logs
or embellishments such as pine cones,
vermiculite or rock wool to the heater. Only
use the logs supplied with the unit.
Failure to position the parts in accordance
with diagrams below or to use only parts
specifically approved for this heater
m a y r e s u l t i n p r o p e r t y d a m a g e o r
personal injury.
CSVF20 / VFCS20 LOG PLACEMENT
Figure 13
1. Install back log (#1) on back of burner assembly.
2. Install front log (#2) on 2 pegs on burner assembly.
ROCk WOOL INSTALLATION
CSVF30 / VFCS30 ONLY
1. Break rock wool into dime-sized pieces.
2. Place rock evenly across rock wool tray and front burner
as shown in Figure 14.
•
Rock wool depth must not be more than 1".
•
Do not place rock wool past the bend in rock
wool tray.
•
Do not place rock wool on rear burner.
Rock wool must be placed correctly. Placing
rock wool in wrong area will create high
carbon monoxide.
14
Front Log #2
Figure 13 -
Install Logs on Grate - CSVF20/VFCS20
Bend in Rock
Wool Tray
Rock
Wool
Rock Wood Tray
Figure 14 -
Rock Wool Installation
LOG and ROCk WOOL PLACEMENT
LG938
CSVF20 log place
R E
M O
T E
C O
N T
R O
L
P IL
O T
O F
LG939
CSVF rock wool
Back Log #1
LG938
LG939
F
58D6002