Operating And Maintenance Manual - EBARA 3E Series Original Instructions Manual

Motor-driven in-line pumps
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
OPERATING AND MAINTENANCE MANUAL PART 2
THE USER SHOULD KEEP THIS DOCUMENT
1. INTRODUCTION
EN
This instruction manual is split into two booklets: PART 1,containing
general information regarding our whole product range; and PART
2, containing information specific to the motor-driven pump you have
purchased. The two publications are complementary to each other, so
make sure you have both.
Comply with the instructions contained in them to get the most out of
your motor-driven pump and assure its proper operation. If you need
further information, get in touch with your nearest authorized dealer. If
information in the two parts contradict each other, take PART 2 contain-
ing the product's specific information as valid.
NO PART OF THESE ILLUSTRATIONS AND/OR TEXT MAY BE RE-
PRODUCED FOR ANY REASON.
The following symbols have been used in the compilation of this in-
struction booklet:
WARNING!
Risk of damaging the pump or the system
Risk of causing injury and damaging property
Electric Hazard
Risk from Hot surface
2. CONTENTS
1. INTRODUCTION
2. CONTENTS
3. DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP
4. SPECIFICATIONS
5. PREPARING FOR USE
6. DIAGRAMS AND DRAWING
3. DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP
3.1 DESCRIPTION
MODEL/Type
Cast iron
3E
X
3ES
X
The motor-driven pumps are employed to handle cold and hot water
(see section 4) and are used in permanent installations. They are built
with materials assuring long life and consistent performance if used
ac- cording to the instructions given in Part 1 and 2 of the manual.
Their special construction means they can be disassembled to service
the motor and replace the impeller and mechanical seal without having
to disconnect the pump casing from the suction and delivery lines.
They are designed for low and medium delivery rates in conformity
with EN 733 DIN 24255 standards and other corresponding European
standards.
3.2 USE FOR WHICH PUMPS ARE DESIGNED
The motor-driven pumps can be used for the following applications:
RESIDENTIAL AND COMMERCIAL: General water supply, water
4
Description
Inline End suction close coupled cast iron pump
Inline End suction close coupled with flanged
motors and rigid coupling
lifting, swimming pool, pressure boosting systems, air-conditioning,
cooling.
FARMING: sprinkler or flood irrigation.
INDUSTRIAL: water handling, Chilling unit, Boiler, Heat Exchanger,
coolant unit.
Use the motor-driven pump based on its technical specifications.
3.3 USE FOR WHICH PUMPS ARE NOT DESIGNED
3E inline motor-driven pumps cannot be used to handle dirty water,
water containing acids and corrosive liquids in general, water with tem-
peratures higher than those mentioned in section 4, saltwater, flamma-
ble liquids and hazardous liquids in general.
The motor-driven pumps must never be made to work without
liquid.
4. SPECIFICATIONS
4.1 PUMP SPECIFICATIONS
Temperature of liquid pumped
Suction diameter
Delivery diameter
Maximum working pressure
4.2 MOTOR SPECIFICATIONS
TYPE
RATINGS
OVERLOAD PROTECTION
4.3 INFORMATIONS ON AIRBORNE NOISE
page 4
page 4
Power
Motor shaft height
page 4
[kW]
[mm]
page 4
3E
page 5
0,37
80
page 5
0,55
80
0,75
90
1,1
90
1,5
90
2,2
90
3
100
4
100
5,5
112
7,5
112
9,2
132
11
132
15
132
15
160
18,5
160
22
160
30
-
37
-
Power
Motor shaft height
[kW]
[mm]
3E
≤3
71-100
*Sound pressure level - Mean value of measurements taken 1 m from the pump.
Tolerance ±2.5 dB.
U/M
°C
mm
32-40-50-65-80-100
mm
32-40-50-65-80-100
MPa
TEFC
See motor-driven pump rating plate
THREE PHASE: prepared by
installer
50Hz LpA
[dB] (A)*
3ES
3E
3ES
3E
-
<70
-
80
<70
<70
80
<70
<70
<70
80
<70
<70
90
<70
<70
90
<70
<70
100
76
<70
112
76
<70
132
79
72
132
79
72
132
82
72
160
82
74
160
80
74
160
86
74
88-87
160
86
74
88-87
180
86
77
88-87
200
-
78
200
-
78
4pole 50Hz LpA
[dB] (A)*
3ES
3E
71-100
<70
3E/3ES
-10 to 120
1.0/1.6
60Hz LpA
[dB] (A)*
3ES
-
-
-
-
-
72
<70
72
70
72
70
76
74
76
78
80
82
80
82
85
82
85
84
85
84
84
84
85
-
87
-
87
3ES
<70

Advertisement

Table of Contents
loading

This manual is also suitable for:

3e3es

Table of Contents